Use of aluminum strips to fabricate verification jig for an implant-supported fixed partial denture.

Authors :
Papazian S
Morgano SM
Source :
The Journal of prosthetic dentistry [J Prosthet Dent] 1998 Mar; Vol. 79 (3), pp. 350-2.
Publication Year :
1998

Abstract

Verification of the accuracy of the master cast for an implant-supported fixed partial denture will reduce the chair time and laboratory costs of implant prosthodontic treatment. A wire is usually luted in the mouth to machined components that have been secured to the implants, and the luted assembly is then transferred to the cast to evaluate the positional accuracy of the implant analogs. Unless this wire is dead soft, inaccuracies as a result of elastic memory of the wire can occur. Also, if the wire is not completely rigid, it can be distorted during handling. This article describes a more reliable verification jig for an implant-supported fixed partial denture that can be fabricated with 1.5 mm thick aluminum strips that are luted to the implant components. The use of two aluminum strips creates a metal framework that is rigid and not easily distorted. Also the aluminum pieces do not have elastic memory because they were cut and not bent to shape.