Back to Search
Start Over
Staphylococcus aureus bloodstream infections among patients undergoing electroconvulsive therapy traced to breaks in infection control and possible extrinsic contamination by propofol.
- Source :
-
Anesthesia and analgesia [Anesth Analg] 1997 Aug; Vol. 85 (2), pp. 420-5. - Publication Year :
- 1997
-
Abstract
- Infectious complications associated with electroconvulsive therapy (ECT) are extremely unusual. When five of nine patients undergoing ECT at one facility on June 20, 1996 developed Staphylococcus aureus bloodstream infection (BSI), an investigation was initiated. A retrospective cohort study, a procedure review, and observational and microbiologic studies were performed. A case was defined as any patient who had ECT at Facility A from June 1, 1995 through June 20, 1996 and developed S. aureus BSI <30 days after ECT. The post-ECT S. aureus BSI rate was significantly greater on the epidemic day than the pre-epidemic period, (i.e., June 1, 1995 through June 19, 1996) (5 of 9 vs 0 of 54 patients, P < 0.001). All patients during the study period received propofol before ECT. Case patients were more likely than noncase patients to have higher maximum temperature after ECT (median 103.9 degrees F vs 100.0 degrees F, P < 0.03) and a greater time from preparation of intravenous medications to infusion (median 2.1 vs 1.1 h, P = 0.01). All case-patient S. aureus isolates were indistinguishable by pulsed field gel electrophoresis. Our investigation suggests that the ECT-associated S. aureus BSIs were associated with infection control breaks, which possibly led to the extrinsic contamination of propofol. Prevention of propofol-associated infectious complications requires aseptic preparation and use immediately before infusion.
- Subjects :
- Aged
Aged, 80 and over
Anesthetics, Intravenous adverse effects
Bacteremia prevention & control
Cohort Studies
Drug Contamination
Electrophoresis, Gel, Pulsed-Field
Female
Fever etiology
Hand microbiology
Humans
Male
Middle Aged
Nose microbiology
Peer Review, Health Care
Retrospective Studies
Staphylococcus aureus classification
Staphylococcus aureus isolation & purification
Time Factors
Bacteremia microbiology
Electroconvulsive Therapy
Infection Control
Propofol adverse effects
Staphylococcal Infections prevention & control
Subjects
Details
- Language :
- English
- ISSN :
- 0003-2999
- Volume :
- 85
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Anesthesia and analgesia
- Publication Type :
- Academic Journal
- Accession number :
- 9249124
- Full Text :
- https://doi.org/10.1097/00000539-199708000-00031