Back to Search Start Over

Complications of transpedicular lumbosacral fixation for non-traumatic disorders.

Authors :
Pihlajämaki H
Myllynen P
Böstman O
Source :
The Journal of bone and joint surgery. British volume [J Bone Joint Surg Br] 1997 Mar; Vol. 79 (2), pp. 183-9.
Publication Year :
1997

Abstract

We analysed the complications encountered in 102 consecutive patients who had posterolateral lumbosacral fusion performed with transpedicular screw and rod fixation for non-traumatic disorders after a minimum of two years. Of these, 40 had spondylolysis and spondylolisthesis, 42 a degenerative disorder, 14 instability after previous laminectomy and decompression, and six pain after nonunion of previous attempts at spinal fusion without internal fixation. There were 75 multilevel and 27 single-level fusions. There were 76 individual complications in 48 patients, and none in the other 54. The complications seen were screw misplacement, coupling failure of the device, wound infection, nonunion, permanent neural injury, and loosening, bending and breakage of screws. Screw breakage or loosening was more common in patients with multilevel fusions (p < 0.001). Screws of 5 mm diameter should not be used for sacral fixation. Forty-six patients had at least one further operation for one or several complications, including 20 fusion procedures for nonunion. The high incidence of complications is a disadvantage of this technically-demanding method.

Details

Language :
English
ISSN :
0301-620X
Volume :
79
Issue :
2
Database :
MEDLINE
Journal :
The Journal of bone and joint surgery. British volume
Publication Type :
Academic Journal
Accession number :
9119839
Full Text :
https://doi.org/10.1302/0301-620x.79b2.7224