Back to Search Start Over

Both blood and crystalloid-based extracellular solutions are superior to intracellular solutions for lung preservation.

Authors :
Binns OA
DeLima NF
Buchanan SA
Cope JT
King RC
Marek CA
Shockey KS
Tribble CG
Kron IL
Source :
The Journal of thoracic and cardiovascular surgery [J Thorac Cardiovasc Surg] 1996 Dec; Vol. 112 (6), pp. 1515-21.
Publication Year :
1996

Abstract

Objective: Lung transplantation remains limited by donor organ ischemic time, inadequate graft preservation, and reperfusion injury. We evaluated lung preservation with use of an extracellular solution, with or without the addition of blood, as compared with preservation with the intracellular Euro-Collins solution.<br />Methods: With use of an isolated, whole blood perfused/ventilated rabbit lung model, we studied three groups of animals. Lungs were flushed with Euro-Collins, low-potassium dextran, or 20% blood-low-potassium dextran solution. Lungs were harvested en bloc, stored inflated at 4 degrees C for 18 hours, and then reperfused at 60 ml/min with whole blood. Continuous measurements of pulmonary artery pressure, pulmonary vascular resistance, and dynamic airway compliance were obtained. Fresh, nonrecirculated venous blood was used to determine the single-pass pulmonary venous-arterial oxygen gradient.<br />Results: Lungs preserved with Euro-Collins solution demonstrated elevated pulmonary artery pressure and pulmonary vascular resistance when compared with those preserved with low-potassium dextran and 20% blood-low-potassium dextran solutions (pulmonary artery pressure: 40.8 +/- 2.2 mm Hg vs 28.9 +/- 2.4 mm Hg and 28.3 +/- 1.5 mm Hg, respectively, p < 0.001; pulmonary vascular resistance: 46.0 +/- 3.1 x 10(3) dynes x sec x cm(-5) vs 29.0 +/- 4.2 x 10(3) dynes x sec x cm(-5) and 28.8 +/- 2.3 x 10(3) dynes x sec x cm(-5), respectively, p < 0.001). Euro-Collins solution-preserved lungs demonstrated a significant drop in compliance when compared with those preserved with low-potassium dextran and 20% blood-low-potassium dextran (-21.9% +/- 4.7% vs 1.8% +/- 3.3% and 1.4% +/- 6.2%, respectively; p = 0.002). Oxygenation was improved with low-potassium dextran and 20% blood-low-potassium dextran solutions as compared with that with Euro-Collins solution (296.3 +/- 54.6 mm Hg and 290.2 +/- 66.4 mm Hg, respectively, vs 37.2 +/- 4.6 mm Hg; p = 0.001).<br />Conclusions: Extracellular solutions provided superior preservation of pulmonary function in this rabbit lung model of ischemia-reperfusion. However, the addition of blood does not confer any demonstrable advantage over low-potassium dextran solution alone with use of an 18-hour period of cold ischemia.

Details

Language :
English
ISSN :
0022-5223
Volume :
112
Issue :
6
Database :
MEDLINE
Journal :
The Journal of thoracic and cardiovascular surgery
Publication Type :
Academic Journal
Accession number :
8975843
Full Text :
https://doi.org/10.1016/S0022-5223(96)70010-7