Back to Search Start Over

Colorimetric assay of benzocaine and some dosage forms.

Authors :
Tan HS
Bruemmer GA
Shelton D
Source :
Journal of pharmaceutical sciences [J Pharm Sci] 1977 Jul; Vol. 66 (7), pp. 1037-9.
Publication Year :
1977

Abstract

A colorimetric procedure for benzocaine and a number of its dosage forms was developed; it offers improvement in ease, speed, and sensitivity over the official method. The method is based on the formation of a red Schiff base between benzocaine and p-dimethylaminocinnamaldehyde in a nonaqueous acidic medium. At the maximum absorption of 544 nm, the Beer-Lambert law was adhered to over the 0.025--2.5-microgram/ml range. Best accuracy can be obtained for solutions containing 0.25--1.25 microgram/ml. The color was stable for at least 2 hr. Analysis of benzocaine in the dosage forms studied can be directly performed without prior drug extraction.

Details

Language :
English
ISSN :
0022-3549
Volume :
66
Issue :
7
Database :
MEDLINE
Journal :
Journal of pharmaceutical sciences
Publication Type :
Academic Journal
Accession number :
886440
Full Text :
https://doi.org/10.1002/jps.2600660736