Back to Search Start Over

[Eradication of Legionella from warm water systems--documentation of our own experiences with thermal disinfection].

Authors :
Linde HJ
Hengerer A
Voggesberger E
Hecht J
Ehret W
Wolf H
Source :
Zentralblatt fur Hygiene und Umweltmedizin = International journal of hygiene and environmental medicine [Zentralbl Hyg Umweltmed] 1995 Jun; Vol. 197 (5), pp. 441-51.
Publication Year :
1995

Abstract

A nosocomial case of Legionellosis in a recently built hospital was the reason for an investigation and thermal disinfection of the complete warm water distribution system. Furthermore weak points in the tubing of the warm water system, which promoted the contamination of potable water, were eliminated as far as technically possible. A lasting reduction of the numbers of Legionella spp. isolated could be measured (factor 10-1000), but a complete decontamination of the warm water distribution system was not possible. As Legionella spp. may cause serious infections in immunodeficient patients, additional measures for the disinfection of the hospital water distribution system must be taken into consideration.

Details

Language :
German
ISSN :
0934-8859
Volume :
197
Issue :
5
Database :
MEDLINE
Journal :
Zentralblatt fur Hygiene und Umweltmedizin = International journal of hygiene and environmental medicine
Publication Type :
Academic Journal
Accession number :
8672226