Back to Search
Start Over
Retrieval of a lost coronary stent from the descending aorta using a PTCA balloon and biopsy forceps.
- Source :
-
Catheterization and cardiovascular diagnosis [Cathet Cardiovasc Diagn] 1993 Apr; Vol. 28 (4), pp. 351-3. - Publication Year :
- 1993
-
Abstract
- We report a case of unsuccessful stenting of a right coronary artery after acute dissection during percutaneous transluminal coronary angioplasty (PTCA). The stent was lost in the descending aorta and we used an original technique to remove it from the arterial bed by using both a very low profile balloon and a 6F bioptome.
- Subjects :
- Aortic Dissection etiology
Aortic Dissection therapy
Angioplasty, Balloon, Coronary adverse effects
Coronary Aneurysm etiology
Coronary Aneurysm therapy
Humans
Intraoperative Complications
Male
Middle Aged
Angioplasty, Balloon, Coronary instrumentation
Aorta, Thoracic
Biopsy instrumentation
Foreign Bodies therapy
Stents
Subjects
Details
- Language :
- English
- ISSN :
- 0098-6569
- Volume :
- 28
- Issue :
- 4
- Database :
- MEDLINE
- Journal :
- Catheterization and cardiovascular diagnosis
- Publication Type :
- Academic Journal
- Accession number :
- 8462088
- Full Text :
- https://doi.org/10.1002/ccd.1810280417