Back to Search
Start Over
Temperature may be an appropriate sensor for chronotropically incompetent patients with postural syncope.
- Source :
-
Pacing and clinical electrophysiology : PACE [Pacing Clin Electrophysiol] 1994 Oct; Vol. 17 (10), pp. 1655-64. - Publication Year :
- 1994
-
Abstract
- Chronotropically incompetent patients benefit most from sensor driven rate response during exercise. Postural syncope may occur despite the chronotropic response because of the failure of currently available sensors to respond physiologically to postural changes. Seven chronotropically incompetent patients with postural syncope who had a dual chamber rate adaptive pacemaker (Circadia) that modulates heart rate in response to temperature change were studied with respect to: (1) response to exercise; and (2) head-up tilt (HUT). During exercise, continuous-wave Doppler of aortic velocities and two-dimensional echocardiographic derived measurements of left ventricular systolic function were used to assess cardiac function. Patients exercised longer (by an average of 168 sec) in the DDDR compared to the DDI mode (P = 0.013). Increase in exercise duration was due mostly to the sensor driven increase during DDDR pacing. During DDDR pacing, heart rate increased from 71 +/- 6 to 121 +/- 17 ppm compared to 70 +/- 1 to 103 +/- 21 ppm for the DDI pacing (P = 0.038). Stroke volume as assessed by Doppler derived stroke distance (SD) contributed more significantly to the cardiac output increase during exercise in the DDI mode (SD increased from 13.4 +/- 4 to 18 +/- 7 cm in DDI compared to 13 +/- 4 to 14 +/- 2 cm in DDDR mode), although these mechanisms were insufficient to fully compensate for failure of appropriate chronotropic response. In response to the HUT, right ventricular temperature increased from 36.78 degrees C +/- 0.29 degrees C to 36.89 degrees +/- 0.28 degrees C (P = 0.0002), and heart rate increased from 54 +/- 3 to 71 +/- 8 ppm (P = 0.0003) in the DDDR mode. No significant change in heart rate occurred in the DDI mode in response to the HUT. Strong positive correlation of temperature and heart rate was noted in all patients in response to HUT (P = 0.001, R2 = 0.755-0.976). We conclude that temperature sensor responds physiologically to exercise and HUT. Therefore, temperature sensing rate adaptive dual chamber pacing may be appropriate for chronotropically incompetent patients with posture related syncope.
- Subjects :
- Aged
Bradycardia complications
Bradycardia physiopathology
Cardiac Pacing, Artificial methods
Exercise Test
Exercise Tolerance physiology
Heart Rate
Humans
Middle Aged
Myocardial Contraction physiology
Syncope physiopathology
Syncope prevention & control
Tilt-Table Test
Ventricular Function, Right physiology
Body Temperature physiology
Bradycardia therapy
Pacemaker, Artificial
Posture physiology
Syncope etiology
Subjects
Details
- Language :
- English
- ISSN :
- 0147-8389
- Volume :
- 17
- Issue :
- 10
- Database :
- MEDLINE
- Journal :
- Pacing and clinical electrophysiology : PACE
- Publication Type :
- Academic Journal
- Accession number :
- 7800568
- Full Text :
- https://doi.org/10.1111/j.1540-8159.1994.tb02360.x