[NMR tomographic measurement of femoral ante-torsion and tibial torsion].

Authors :
Schneider B
Laubenberger J
Wildner M
Exne V
Langer M
Source :
RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin [Rofo] 1995 Mar; Vol. 162 (3), pp. 229-31.
Publication Year :
1995

Abstract

Purpose: A new MRI method for the measurement of femoral torsion and tibial torsion is presented.<br />Methods: Axial images were generated using a standard gradient echo sequence (FLASH 2D). Otherwise measurement of femoral and tibial torsion was performed according to an established CT method.<br />Results: The torsion angles measured using MRI were in accordance with the angles measured using the CT method. The MRI method was not more time-consuming than the CT method.<br />Conclusion: In respect of radiation exposure, MRI determination of femoral and tibial torsion should be considered particularly in children and patients who have to undergo repeated torsion measurements.

Details

Language :
German
ISSN :
1438-9029
Volume :
162
Issue :
3
Database :
MEDLINE
Journal :
RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin
Publication Type :
Academic Journal
Accession number :
7718778
Full Text :
https://doi.org/10.1055/s-2007-1015870