Back to Search
Start Over
The voxel sensitivity function in Fourier transform imaging: applications to magnetic resonance angiography.
- Source :
-
Magnetic resonance in medicine [Magn Reson Med] 1995 Feb; Vol. 33 (2), pp. 156-62. - Publication Year :
- 1995
-
Abstract
- In this paper the problem of small structure visualization in magnetic resonance imaging (MRI) is considered. The relationship between the structure and the image intensities is defined in terms of the voxel sensitivity function (VSF). Using the VSF, the spatial dependence of the voxel signal for small spheres and cylinders is computed. Although the spatial fluctuation is smaller in the MRI VSF than that which would be obtained from a uniformly sensitive cubical voxel, the deviation still results in significant signal loss near the edges and corners of the voxels. Finally, the VSF formalism is used to demonstrate the improvement in signal uniformity that can be obtained by using zero-filled (band-limited or sinc) interpolation.
- Subjects :
- Algorithms
Blood Vessels pathology
Humans
Image Processing, Computer-Assisted statistics & numerical data
Models, Statistical
Regional Blood Flow physiology
Fourier Analysis
Image Enhancement methods
Magnetic Resonance Angiography methods
Magnetic Resonance Angiography statistics & numerical data
Subjects
Details
- Language :
- English
- ISSN :
- 0740-3194
- Volume :
- 33
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Magnetic resonance in medicine
- Publication Type :
- Academic Journal
- Accession number :
- 7707904
- Full Text :
- https://doi.org/10.1002/mrm.1910330203