Back to Search Start Over

A field method for sampling benzene in end-exhaled air.

Authors :
Ljungkvist GM
Nordlinder RG
Source :
American Industrial Hygiene Association journal [Am Ind Hyg Assoc J] 1995 Jul; Vol. 56 (7), pp. 693-7.
Publication Year :
1995

Abstract

A simple and reliable field method is presented for sampling and analysis of benzene in end-exhaled air. The sample is collected directly on an adsorbent tube while the subject exhales through a sampling device consisting of a modified peak expiratory flow meter. To ensure sampling of end-exhaled air, the temperature of the breath is monitored during expiration. The analytes subsequently are thermally desorbed and analyzed by gas chromatography. No sample preparation before analysis is needed, and therefore sample loss is minimized, shipping is easy, storage is possible, and clean up is unnecessary. All these steps have been major problems in earlier methods for breath analysis. The presented method has been applied to the monitoring of benzene. The separation of benzene from other components of exhaled air was good and the detection limit low (0.5 microgram/m3), and therefore benzene could be monitored in occupationally nonexposed nonsmokers. No carry-over in the sampling device or breakthrough could be detected. The samples were stable for at least a week. The combined precision in sampling and analysis was excellent, with a coefficient of variation of 13%.

Details

Language :
English
ISSN :
0002-8894
Volume :
56
Issue :
7
Database :
MEDLINE
Journal :
American Industrial Hygiene Association journal
Publication Type :
Academic Journal
Accession number :
7618607
Full Text :
https://doi.org/10.1080/15428119591016719