Improved high-performance liquid chromatographic procedure for the determination of tetracyclines in plasma, urine and tissues.

Authors :
Sharma JP
Bevill RF
Source :
Journal of chromatography [J Chromatogr] 1978 Dec 01; Vol. 166 (1), pp. 213-20.
Publication Year :
1978

Abstract

An improved extraction procedure for the determination of oxytetracycline, tetracycline and chlortetracycline in urine, plasma and tissues by high-performance liquid chromatography is described. The addition of phenylbutazone (3,5-dioxo-1,2-diphenyl-4-n-butylpyrazolidine) to water, urine or plasma enhances the extraction of these compounds by ethyl acetate. The recovery of oxytetracycline from plasma is increased six fold and the need for two separate extractions of urine and plasma is eliminated. The formation of phenylbutazone-tetracycline ion pairs and their role in the extraction process is discussed.

Details

Language :
English
Volume :
166
Issue :
1
Database :
MEDLINE
Journal :
Journal of chromatography
Publication Type :
Academic Journal
Accession number :
744780
Full Text :
https://doi.org/10.1016/s0021-9673(00)92264-7