Back to Search Start Over

Comparison of fixation of spinal fractures.

Authors :
Laborde JM
Bahniuk E
Bohlman HH
Samson B
Source :
Clinical orthopaedics and related research [Clin Orthop Relat Res] 1980 Oct (152), pp. 303-10.
Publication Year :
1980

Abstract

Mechanical failure was induced in cadaver spines by applying flexion, extension, and lateral bending loads with continuous recordings of moment and rotation. Each spine was then stabilized with Harrington distraction rods, compression rods, and titanium mesh in sequence, and tested in a similar manner. The spines stabilized with mesh appeared stronger but less stiff than spines stabilized with Harrington rods.

Details

Language :
English
ISSN :
0009-921X
Issue :
152
Database :
MEDLINE
Journal :
Clinical orthopaedics and related research
Publication Type :
Academic Journal
Accession number :
7438621