Back to Search Start Over

Morphological changes in isolated lymphocytes during preparation for SEM: freeze drying versus critical-point drying.

Authors :
Billings-Gagliardi S
Pockwinse SM
Schneider GB
Source :
The American journal of anatomy [Am J Anat] 1978 Jul; Vol. 152 (3), pp. 383-9.
Publication Year :
1978

Abstract

A quantitative comparison of isolated lymphocytes prepared for SEM by the critical-point drying (CPD) and freeze drying (FD) methods revealed that the mean cellular diameter dropped from 7.9 micron after fixation to a final diameter 6.9 micron after FD, and to 5.7 micron after CPD. In addition to their larger sizes, FD lymphocytes were immediately distinguishable by their more complex surfaces, featuring wider microvilli which often emanated from ridges on the cell surface and branched extensively near their bases. The mean width of microvilli was 0.22 micron after FD and 0.12 micron after CPD. The number of microvilli per cell was essentially the same by the two methods. In view of these findings, a critical comparison of the CPD and FD methods using the particular cells or tissue to be investigated is an essential prelude to a rigorous SEM study.

Details

Language :
English
ISSN :
0002-9106
Volume :
152
Issue :
3
Database :
MEDLINE
Journal :
The American journal of anatomy
Publication Type :
Academic Journal
Accession number :
677056
Full Text :
https://doi.org/10.1002/aja.1001520308