Back to Search Start Over

[Dosimetric study in vivo, using a computer, of Co-60 irradiation of patients with breast prosthesis made of silicone].

Authors :
Sala S
Barboni G
Giordana C
Malinverni G
Baruffaldi M
Nasi P
Violante R
Source :
La Radiologia medica [Radiol Med] 1984 Dec; Vol. 70 (12), pp. 987-92.
Publication Year :
1984

Abstract

This work studies the dose distribution through the chest wall in radiation therapy after mammary reconstruction with silicone prostheses. TLD experimental dosimetry has been done on patient with silicone prostheses, on patient without prostheses and on Alderson phantom. Various conditions of treatment have been theorically simulated on a computer. At least authors show the results evaluating the dose distribution through the chest wall, the skin and the local complications.

Details

Language :
Italian
ISSN :
0033-8362
Volume :
70
Issue :
12
Database :
MEDLINE
Journal :
La Radiologia medica
Publication Type :
Academic Journal
Accession number :
6545616