Back to Search Start Over

Quantitation of cocaine, benzoylecgonine and ecgonine methyl ester by GC-CI-SIM after Extrelut extraction.

Authors :
Matsubara K
Maseda C
Fukui Y
Source :
Forensic science international [Forensic Sci Int] 1984 Nov; Vol. 26 (3), pp. 181-92.
Publication Year :
1984

Abstract

A method of gas chromatography-chemical ionization selected ion monitoring (GC-CI-SIM) is described for the determination of cocaine, benzoylecgonine and ecgonine methyl ester in biological materials using an Extrelut extraction technique. Recoveries of cocaine, benzoylecgonine and ecgonine methyl ester by this technique were 95, 81 and 97%, respectively. The method uses cocaine-d5, benzoylecgonine-d5 and lidocaine as internal standards, and isobutane as reagent gas for chemical ionization. Sensitivity of the method proved to be 1 ng/ml for cocaine and benzoylecgonine, and 10 ng/ml for ecgonine methyl ester when used in a 10-ml urine sample. With animal experiments, ecgonine methyl ester as well as benzoylecgonine was confirmed as a major metabolite of cocaine.

Details

Language :
English
ISSN :
0379-0738
Volume :
26
Issue :
3
Database :
MEDLINE
Journal :
Forensic science international
Publication Type :
Academic Journal
Accession number :
6510854
Full Text :
https://doi.org/10.1016/0379-0738(84)90216-0