Back to Search
Start Over
Contaminant electrons in the build-up region of a 4 MV photon beam.
- Source :
-
Physics in medicine and biology [Phys Med Biol] 1983 Jun; Vol. 28 (6), pp. 659-65. - Publication Year :
- 1983
-
Abstract
- The per cent ionisation curves for the 4 MV photon beam from a Clinac 4 exhibit pronounced enhancement with field size in the build-up region. The source and nature of this increase is investigated by analysing the radiation components of the 4 MV photon beam with a 0.23 T magnetic field. The build-up ionisation curves were measured at 86 cm SSD with a parallel-plate ionisation chamber embedded in a polystyrene phantom. The surface ionisation increases from 18% to 32% as the field size is increased from 4.3 cm X 4.3 cm to 9.7 cm X 32.3 cm. With the electromagnet placed beside the treatment head, the field size dependence reduces to 16% to 24%. This and similar results at 113.2 cm SSD, clearly demonstrate that electrons from the Clinac 4 treatment head are responsible for approximately half the observed increase in the surface ionisation with field size.
Details
- Language :
- English
- ISSN :
- 0031-9155
- Volume :
- 28
- Issue :
- 6
- Database :
- MEDLINE
- Journal :
- Physics in medicine and biology
- Publication Type :
- Academic Journal
- Accession number :
- 6410419
- Full Text :
- https://doi.org/10.1088/0031-9155/28/6/006