Back to Search Start Over

A precise and sensitive method for measurement of spinal cord blood flow.

Authors :
Zivin JA
Waud DR
Source :
Brain research [Brain Res] 1983 Jan 10; Vol. 258 (2), pp. 197-200.
Publication Year :
1983

Abstract

Spinal cord blood flow can be accurately and rapidly measured in rabbits by intravenous injection of [14C]iodoantipyrine, collection of sequential arterial samples, and abrupt termination of blood flow to the spinal cord by severing the aorta with a previously implanted ligature. The radioactive tracer concentrations in arterial and spinal cord samples can be rapidly measured in a scintillation counter. The spinal cord blood flow can then be calculated from these blood and tissue tracer concentrations. This method is suitable for use in anesthetized or unanesthetized small animals.

Details

Language :
English
ISSN :
0006-8993
Volume :
258
Issue :
2
Database :
MEDLINE
Journal :
Brain research
Publication Type :
Academic Journal
Accession number :
6337683
Full Text :
https://doi.org/10.1016/0006-8993(83)91142-3