Back to Search Start Over

Evaluation of esophageal transit in children and in infants by means of Krypton-81m.

Authors :
Ham HR
Piepsz A
Georges B
Delaet MH
Rodesch P
Guillaume M
Cadranel S
Source :
Pediatric radiology [Pediatr Radiol] 1985; Vol. 15 (3), pp. 161-4.
Publication Year :
1985

Abstract

This paper presents the results of Krypton-81m esophageal transit study in a series of children and infants presenting various esophageal disorders. The advantage of Kr-81m, compared to other radionuclides, is that the radiation dose to the patient is extremely low. The study can therefore be repeated as often as necessary and a high dose can be given to ensure good quality results. The method is very easy to perform and allows a quantitative assessment of esophageal transit in physiological conditions. The method gives information about the severity of altered transit and it is particularly useful in studying the effects of treatment.

Details

Language :
English
ISSN :
0301-0449
Volume :
15
Issue :
3
Database :
MEDLINE
Journal :
Pediatric radiology
Publication Type :
Academic Journal
Accession number :
3991257
Full Text :
https://doi.org/10.1007/BF02388602