Back to Search
Start Over
Validation of a data-driven motion-compensated PET brain image reconstruction algorithm in clinical patients using four radiotracers.
- Source :
-
EJNMMI physics [EJNMMI Phys] 2025 Feb 03; Vol. 12 (1), pp. 11. Date of Electronic Publication: 2025 Feb 03. - Publication Year :
- 2025
-
Abstract
- Purpose: Patients with dementia symptoms often struggle to limit movements during PET examinations, necessitating motion compensation in brain PET imaging to ensure the high image quality needed for diagnostic accuracy. This study validates a data-driven motion-compensated (MoCo) PET brain image reconstruction algorithm that corrects head motion by integrating the detected motion frames and their associated rigid body transformations into the iterative image reconstruction. Validation was conducted using phantom scans, healthy volunteers, and clinical patients using four radiotracers with distinct tracer activity distributions.<br />Methods: We conducted technical validation experiments of the algorithm using Hoffman brain phantom scans during a series of controlled movements, followed by two blinded reader studies assessing image quality between standard images and MoCo images in 38 clinical patients receiving dementia scans with [ <superscript>18</superscript> F]Fluorodeoxyglucose, [ <superscript>18</superscript> F]N-(3-iodopro-2E-enyl)-2beta-carbomethoxy-3beta-(4'-methylphenyl)-nortropane, [ <superscript>18</superscript> F]flutemetamol, and a research group comprising 25 elderly subjects scanned with [ <superscript>18</superscript> F]fluoroethoxybenzovesamicol.<br />Results: The Hoffman brain phantom study demonstrated the algorithm's capability to detect and correct for even minimal movements, 1-mm translations and 1⁰ rotations, applied to the phantom. Within the clinical cohort, where standard images were deemed suboptimal or non-diagnostic, all MoCo images were classified as having acceptable diagnostic quality. In the research cohort, MoCo images consistently matched or surpassed the standard image quality even in cases with minimal head movement, and the MoCo algorithm never led to degraded image quality.<br />Conclusion: The PET brain MoCo reconstruction algorithm was robust and worked well for four different tracers with markedly different uptake patterns. Moco images markedly improved the image quality for patients who were unable to lie still during a PET examination and obviated the need for any repeat scans. Thus, the method was clinically feasible and has the potential for improving diagnostic accuracy.<br />Competing Interests: Declarations. Ethics approval: The research study was conducted according to the Declaration of Helsinki and approved by the Regional Ethics Committee (project number 1-10-72-270-19). Consent to participate: Informed consent was obtained from all individual participants included in the research study. Consent to publish: Publication consent was obtained from all research study participants. Competing interests: The authors JJ, IH and SZ are full-time employees of Siemens Medical Solutions USA, Inc. ABR is a full-time employee of Siemens Healthcare A/S Denmark. No other potential conflicts of interest relevant to this article have been reported.<br /> (© 2025. The Author(s).)
Details
- Language :
- English
- ISSN :
- 2197-7364
- Volume :
- 12
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- EJNMMI physics
- Publication Type :
- Academic Journal
- Accession number :
- 39899171
- Full Text :
- https://doi.org/10.1186/s40658-025-00723-w