PE-CycleGAN network based CBCT-sCT generation for nasopharyngeal carsinoma adaptive radiotherapy.
- Source :
-
Nan fang yi ke da xue xue bao = Journal of Southern Medical University [Nan Fang Yi Ke Da Xue Xue Bao] 2025 Jan 20; Vol. 45 (1), pp. 179-186. - Publication Year :
- 2025
-
Abstract
- Objectives: To explore the synthesis of high-quality CT (sCT) from cone-beam CT (CBCT) using PE-CycleGAN for adaptive radiotherapy (ART) for nasopharyngeal carcinoma.<br />Methods: A perception-enhanced CycleGAN model "PE-CycleGAN" was proposed, introducing dual-contrast discriminator loss, multi-perceptual generator loss, and improved U-Net structure. CBCT and CT data from 80 nasopharyngeal carcinoma patients were used as the training set, with 7 cases as the test set. By quantifying the mean absolute error (MAE), peak signal-to-noise ratio (PSNR), structural similarity index (SSIM), as well as the dose gamma pass rate and the relative dose deviations of the target area and organs at risk (OAR) between sCT and reference CT, the image quality and dose calculation accuracy of sCT were evaluated.<br />Results: The MAE of sCT generated by PE-CycleGAN compared to the reference CT was (56.89±13.84) HU, approximately 30% lower than CBCT's (81.06±15.86) HU ( P <0.001). PE-CycleGAN's PSNR and SSIM were 26.69±2.41dB and 0.92±0.02 respectively, significantly higher than CBCT's 21.54±2.37dB and 0.86±0.05 ( P <0.001), indicating substantial improvements in image quality and structural similarity. In gamma analysis, under the 2 mm/2% criterion, PE-CycleGAN's sCT achieved a pass rate of (90.13±3.75)%, significantly higher than CBCT's (81.65±3.92)% ( P <0.001) and CycleGAN's (87.69±3.50)% ( P <0.05). Under the 3 mm/3% criterion, PE-CycleGAN's sCT pass rate of (90.13±3.75)% was also significantly superior to CBCT's (86.92±3.51)% ( P <0.001) and CycleGAN's (94.58±2.23)% ( P <0.01). The mean relative dose deviation of the target area and OAR between sCT and planned CT was within ±3% for all regions, except for the Lens Dmax (Gy), which had a deviation of 3.38% ( P =0.09). The mean relative dose deviations for PTVnx HI, PTVnd HI, PTVnd CI, PTV1 HI, PRV&#95;SC, PRV&#95;BS, Parotid, Larynx, Oral, Mandible, and PRV&#95;ON were all less than ±1% ( P >0.05).<br />Conclusions: PE-CycleGAN demonstrates the ability to rapidly synthesize high-quality sCT from CBCT, offering a promising approach for CBCT-guided adaptive radiotherapy in nasopharyngeal carcinoma.
- Subjects :
- Humans
Radiotherapy Planning, Computer-Assisted methods
Carcinoma radiotherapy
Carcinoma diagnostic imaging
Radiotherapy Dosage
Signal-To-Noise Ratio
Algorithms
Nasopharyngeal Neoplasms radiotherapy
Nasopharyngeal Neoplasms diagnostic imaging
Cone-Beam Computed Tomography methods
Nasopharyngeal Carcinoma radiotherapy
Nasopharyngeal Carcinoma diagnostic imaging
Subjects
Details
- Language :
- English; Chinese
- ISSN :
- 1673-4254
- Volume :
- 45
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Nan fang yi ke da xue xue bao = Journal of Southern Medical University
- Publication Type :
- Academic Journal
- Accession number :
- 39819726
- Full Text :
- https://doi.org/10.12122/j.issn.1673-4254.2025.01.21