Back to Search
Start Over
Evaluation of marginal accuracy of polyetheretherketone and zirconia copings fabricated using computer-aided design/computer-aided manufacturing technique: An in vitro study.
- Source :
-
Journal of Indian Prosthodontic Society [J Indian Prosthodont Soc] 2025 Jan 01; Vol. 25 (1), pp. 95-101. Date of Electronic Publication: 2025 Jan 03. - Publication Year :
- 2025
-
Abstract
- Aim: The aim of this study was to compare the marginal accuracy of polyetheretherketone (PEEK) and zirconia copings fabricated using computer-aided design/computer-aided manufacturing (CAD/CAM) technology, and to assess the impact of their material properties on accuracy when produced with a 4-axis milling system under controlled conditions.<br />Settings and Design: The study employed an in vitro design with a stainless steel die model featuring a 6 mm axial wall height, a 6-degree total occlusal convergence, and a radial shoulder finish line.<br />Materials and Methods: Thirty stone dies were created from silicone impressions of the metal die and poured using type-IV dental stone. The dies were divided into two groups: Group-A (PEEK) copings and Group-B (zirconia) copings. All copings were fabricated using a CAD/CAM system. Vertical marginal accuracy was assessed with a stereomicroscope and image analysis software at ×20 magnification. The marginal gaP values were subjected to a student (independent) t-test for statistical analysis.<br />Statistical Analysis Used: The statistical analysis involved a student (independent) t-test to compare the marginal gaP values between Group A (PEEK) and Group B (zirconia).<br />Results: The mean marginal discrepancy for Group A (PEEK) and Group B (zirconia) was 92.84 μm ± 3.48 μm and 63.12 μm ± 31.47 μm, respectively. A statistically significant variation (t = 3.635, P = 0.001) between the groups was observed, indicating better marginal accuracy with zirconia copings compared to PEEK copings.<br />Conclusion: Both PEEK and zirconia copings demonstrated vertical marginal discrepancies within the clinically acceptable limit of <120 μm. However, zirconia copings exhibited superior marginal accuracy in this in vitro study.<br /> (Copyright © 2025 The Journal of Indian Prosthodontic Society.)
Details
- Language :
- English
- ISSN :
- 1998-4057
- Volume :
- 25
- Issue :
- 1
- Database :
- MEDLINE
- Journal :
- Journal of Indian Prosthodontic Society
- Publication Type :
- Academic Journal
- Accession number :
- 39750015
- Full Text :
- https://doi.org/10.4103/jips.jips_8_24