Back to Search Start Over

[Application of High-performance Liquid Chromatography to Caprolactam Migration Testing of Food Utensils, Containers, and Packaging].

Authors :
Abe Y
Yamaguchi M
Fujihara K
Kataoka Y
Mutsuga M
Sugimoto N
Source :
Shokuhin eiseigaku zasshi. Journal of the Food Hygienic Society of Japan [Shokuhin Eiseigaku Zasshi] 2024; Vol. 65 (5), pp. 107-112.
Publication Year :
2024

Abstract

We assessed the applicability of high-performance liquid chromatography (HPLC) to the official testing method for the migration of caprolactam (CPL) from food utensils, containers, and packaging made from polyamide (PA). Hydrophilic interaction chromatography (HILIC) columns coated with unmodified silica, carbamoyl, and aminopropyl were used. Water and acetonitrile (ACN) were used as the mobile phase, and the analytical conditions were optimized. The test solution was diluted 10-fold with ACN, and standard solutions were prepared using 98% ACN. We validated using HPLC as limit testing and quantitative testing methods. Accuracy parameters corresponding to trueness, repeatability, and reproducibility (as intermediate precision) satisfied the target values in both cases, indicating that this method demonstrates good performance as a testing method.

Details

Language :
English
ISSN :
0015-6426
Volume :
65
Issue :
5
Database :
MEDLINE
Journal :
Shokuhin eiseigaku zasshi. Journal of the Food Hygienic Society of Japan
Publication Type :
Academic Journal
Accession number :
39694506
Full Text :
https://doi.org/10.3358/shokueishi.65.107