Back to Search Start Over

A novel augmented reality-based simulator for enhancing orthopedic surgical training.

Authors :
Wu L
Seibold M
Cavalcanti NA
Hein J
Gerth T
Lekar R
Hoch A
Vlachopoulos L
Grabner H
Zingg P
Farshad M
Fürnstahl P
Source :
Computers in biology and medicine [Comput Biol Med] 2025 Feb; Vol. 185, pp. 109536. Date of Electronic Publication: 2024 Dec 12.
Publication Year :
2025

Abstract

Background: Total Hip Arthroplasty (THA) is a well-established and common orthopedic surgery. Due to the complexity involved in THA, orthopedic surgeons require rigorous training. However, the current gold standard, the tutor-guided and -evaluated apprenticeship model is time-consuming, costly, and poses risks to patients. There is a pressing need for additional training resources to enhance the efficiency and safety of the training process. In this work, we present a novel Augmented Reality (AR)-based simulator designed for THA that helps enable a new self-paced training and learning paradigm without the need for instructors.<br />Methods: The simulator reduces the need for instructors by integrating an AR guidance module and an automated performance evaluation module. Three types of AR guidance were developed: Overlay, Virtual Twin, and Sectional Views. A feasibility study was conducted with five resident surgeons and two senior surgeons to compare these guidance methods quantitatively and qualitatively. The automated performance evaluation module was assessed against manual performance evaluation using Bland-Altman analysis with limits of agreement (LoA) and Mann-Whitney U tests.<br />Results: The quantitative feasibility results indicate the efficacy of the developed AR guidance, characterized by mean transitional and rotational deviation errors below 3 mm and 3 degrees. Based on the qualitative results, we provide recommendations for efficient AR guidance designs. The Bland-Altman analysis results (0.22±1.32mm with LoA -2.37 to 2.81 mm for distance deviation, 0.94±2.41 degrees with LoA -3.78 to 5.66 degrees for yaw deviation, -0.34±1.30 degrees with LoA -2.90 to 2.22 degrees for pitch deviation) and p-values of Mann-Whitney U tests (0.64 for distance deviation, 0.12 for yaw deviation, 0.11 for pitch deviation) indicate no statistically significant differences between the automated and manual performance evaluation at a significance level of 0.05.<br />Conclusion: This work shows the potential of AR-based simulators in introducing a novel, data-driven approach to open surgery training in orthopedics, enabling surgeons to individually assess and improve their progress.<br />Competing Interests: Declaration of competing interest We declare the following financial interests/personal relationships which may be considered as potential competing interests: Prof. Mazda Farshad is shareholder and member of the board of directors of Incremed AG, a company developing mixed-reality applications. All other authors declare that they have no conflict of interest.<br /> (Copyright © 2024 The Authors. Published by Elsevier Ltd.. All rights reserved.)

Details

Language :
English
ISSN :
1879-0534
Volume :
185
Database :
MEDLINE
Journal :
Computers in biology and medicine
Publication Type :
Academic Journal
Accession number :
39672013
Full Text :
https://doi.org/10.1016/j.compbiomed.2024.109536