Back to Search
Start Over
Design and Analytical Modeling of a Dumbbell-Shaped Balloon Anchoring Actuator for Safe and Efficient Locomotion Inside Gastrointestinal Tract.
- Source :
-
Soft robotics [Soft Robot] 2024 Dec 02. Date of Electronic Publication: 2024 Dec 02. - Publication Year :
- 2024
- Publisher :
- Ahead of Print
-
Abstract
- Colorectal cancer stands as one of the most prevalent cancers globally, representing 9.8% of total cases and contributing to 9.2% of mortalities annually. Robotic "front-wheel" navigating colonoscopes mitigate aggressive stretching against the long and tortuous colonic wall, alleviating associated discomfort and pain typically experienced by patients inspected by conventional "back-wheel" navigating colonoscopes. The anchoring unit of most "front-wheel" navigating colonoscopes plays a crucial role in ensuring effective locomotion by preventing slipping during elongation/contraction of the central actuation part. The soft balloon anchoring actuator emerges as a promising solution due to its high compliance. This study introduces a dumbbell-shaped balloon anchoring actuator (DBAA) integrating an "inflation and suction" mechanism to address the inherent conflict between achieving sufficient anchoring force and minimizing expansion and potential trauma of the colonic wall, commonly encountered in current balloon anchoring actuators. Analytical modeling of DBAA and soft external lumen, encompassing geometric deformation and anchoring force, were proposed to characterize the actuator and provide guidelines for designing and controlling DBAA in further applications, enabling autonomous anchoring within different diameter lumens and achieving the expected anchoring force. A comprehensive set of validation experiments was conducted, and the outcomes revealed high consistency with analytical predictions, confirming the effectiveness of the proposed analytical modeling approach. Furthermore, the results demonstrated a significant enhancement in anchoring force with the proposed actuator and corresponding mechanism while concurrently maintaining low-lumen expansion. For instance, in a lumen sample with R i n = 15 m m , Λ 2 = 105 % , the anchoring force reaches 14.5 N with 50 kPa negative pressure, which is 12.4 times of the force (1.17 N) observed without applying negative pressure.
Details
- Language :
- English
- ISSN :
- 2169-5180
- Database :
- MEDLINE
- Journal :
- Soft robotics
- Publication Type :
- Academic Journal
- Accession number :
- 39620920
- Full Text :
- https://doi.org/10.1089/soro.2024.0037