Enhancement of measurement range of MicroLiDAR with multi-reference paths.

Authors :
Hayashi N
Ishii K
Deguchi T
Nomura R
Hasegawa H
Furukawa H
Source :
Optics express [Opt Express] 2024 Jul 29; Vol. 32 (16), pp. 28706-28713.
Publication Year :
2024

Abstract

The measurement range of the MicroLiDAR was enhanced with multi-reference paths. The multi-reference paths were composed of four paths with polarization maintaining optical fibers, each with different lengths. 50-mm-long measurement range was demonstrated with an oscilloscope with 15-GHz bandwidth. Reducing the time of calculation of the distance, we induced the dual entry method and demonstrated it. The stable distance measurement was demonstrated up to 50 mm.