Back to Search Start Over

Distance-based paper microfluidic devices for rapid visual quantification of heavy metals in herbal supplements and cosmetics.

Authors :
Manmana Y
Macka M
Nuchtavorn N
Source :
RSC advances [RSC Adv] 2024 Nov 11; Vol. 14 (49), pp. 36142-36151. Date of Electronic Publication: 2024 Nov 11 (Print Publication: 2024).
Publication Year :
2024

Abstract

Distance-based detection (DbD) on paper-based microfluidic analytical devices (μPADs) has emerged as a promising, cost-effective, simple, and instrumentation-free assay method. Broadening the applicability of a new way of immobilization of reagent for DbD on μPADs (DμPADs) is presented, employing an ion exchange (IE) interaction of an anionic metallochromic reagent, 2-(5-bromo-2-pyridylazo)-5-[ N-n -propyl- N -(3-sulfopropyl)amino]phenol (5-Br-PAPS), on the anion-exchange filter paper. The IE DμPADs demonstrate superiority over standard cellulose filter paper in terms of the degree of reagent immobilization, detection sensitivity, and clear detection endpoints due to the strong retention of 5-Br-PAPS. The study investigated various parameters influencing DbD, including 5-Br-PAPS concentrations (0.25-1 mM), buffer types (acetic acid-Tris, MES), buffer concentrations (20-500 mM), and auxiliary complexing agents (acetic, formic, and glycolic acids). Subsequently, the performance of 17 metals (Ag <superscript>+</superscript> , Cd <superscript>2+</superscript> , Co <superscript>2+</superscript> , Cr <superscript>3+</superscript> , Cu <superscript>2+</superscript> , Fe <superscript>2+</superscript> , Hg <superscript>2+</superscript> , La <superscript>2+</superscript> , Mn <superscript>2+</superscript> , Ni <superscript>2+</superscript> , Pb <superscript>2+</superscript> , Ti <superscript>2+</superscript> , Zn <superscript>2+</superscript> , Al <superscript>3+</superscript> , As <superscript>3+</superscript> , Fe <superscript>3+</superscript> , and V <superscript>4+</superscript> ) was evaluated, with color formation observed for 12 metals. Additionally, the paper surface was examined using SEM and SEM-EDX to verify the suitability of certain areas in the detection channel for reagent immobilization and metal binding. This method demonstrates quantitation limits of metals in the low μg mL <superscript>-1</superscript> range, showing great potential for the rapid screening of toxic metals commonly found in herbal supplements and cosmetics regulated by the Food and Drug Administration (FDA). Thus, it holds promise for enhancing safety and regulatory compliance in product quality assessment. Furthermore, this method offers a cost-effective, environmentally sustainable, and user-friendly approach for the rapid visual quantification of heavy metals for in-field analysis, eliminating the need for complex instrumentation.<br />Competing Interests: There are no conflicts to declare.<br /> (This journal is © The Royal Society of Chemistry.)

Details

Language :
English
ISSN :
2046-2069
Volume :
14
Issue :
49
Database :
MEDLINE
Journal :
RSC advances
Publication Type :
Academic Journal
Accession number :
39534052
Full Text :
https://doi.org/10.1039/d4ra05358c