Evaluation of Long-term Rotational Stability and Functional Performance of Two Toric Multifocal IOL Models Beyond 5 Years.
- Source :
-
Journal of refractive surgery (Thorofare, N.J. : 1995) [J Refract Surg] 2024 Nov; Vol. 40 (11), pp. e845-e853. Date of Electronic Publication: 2024 Nov 01. - Publication Year :
- 2024
-
Abstract
- Purpose: To assess visual outcomes and stability of lens alignment more than 3 years after implanting either the AT Lisa Tri Toric (Carl Zeiss Meditec) or the Acrysof IQ Restor Toric (Alcon Laboratories, Inc) intraocular lens (IOL).<br />Methods: Patients who had received either the AT Lisa Tri Toric or the Acrysof IQ Restor Toric IOL were included in the study. The average follow-up period was 5.4 years for the AT Lisa Tri Toric group and 7.9 years for the Acrysof IQ Restor group. The examinations covered included: subjective refraction, monocular and binocular corrected and uncorrected visual acuity at far (4 m), intermediate (75 cm), and near (40 cm) distances, binocular best-corrected defocus curve analysis (4 m), contrast sensitivity evaluation, assessment of IOL axial position, and presence of positive dysphotopsia.<br />Results: A total of 42 eyes were evaluated. Both groups exhibited good long-term lens axial stability. The AT Lisa Tri Toric group had a mean misalignment of 4.8 ± 3.2° from the preoperatively determined axis, whereas the Acrysof IQ Restor Toric group had an average misalignment of 5.4 ± 4.5° (no statistically significant difference, P = .578). Mean achieved spherical equivalent was -0.19 ± 0.36 diopters (D) for the AT Lisa Tri Toric group and 0.15 ± 0.39 D for the Acrysof IQ Restor Toric group. In the AT Lisa Tri Toric group, 18 eyes (72%) achieved an uncorrected distance visual acuity of 0.10 logarithm of the minimum angle of resolution (20/25 Snellen) or better, compared to 15 eyes (88%) in the Acrysof IQ Restor Toric group. Overall, 21 eyes (84%) in the AT Lisa Tri Toric group and 14 eyes (83%) in the Acrysof IQ Restor Toric group achieved a postoperative spherical equivalent refraction between -0.50 and +0.50 D.<br />Conclusions: Both the AT Lisa Tri Toric and the Acrysof IQ Restor Toric IOLs showed good long-term stability and functional outcomes. They proved to be effective options for restoring vision at far, intermediate, and near distances, providing a viable solution for presbyopia correction even several years after implantation. [ J Refract Surg . 2024;40(11):e845-e853.] .<br />Competing Interests: Disclosure: GUA and RK report research grants, travel expenses, lecture fees, and consulting for Alcon Laboratories, Inc, and research grants, travel expenses, and lecture fees for Carl Zeiss Meditec. The remaining authors have disclosed no potential conflicts of interest, financial or otherwise.
- Subjects :
- Humans
Male
Female
Follow-Up Studies
Aged
Middle Aged
Retrospective Studies
Rotation
Lenses, Intraocular
Visual Acuity physiology
Refraction, Ocular physiology
Lens Implantation, Intraocular
Pseudophakia physiopathology
Multifocal Intraocular Lenses
Vision, Binocular physiology
Phacoemulsification
Contrast Sensitivity physiology
Prosthesis Design
Subjects
Details
- Language :
- English
- ISSN :
- 1938-2391
- Volume :
- 40
- Issue :
- 11
- Database :
- MEDLINE
- Journal :
- Journal of refractive surgery (Thorofare, N.J. : 1995)
- Publication Type :
- Academic Journal
- Accession number :
- 39530984
- Full Text :
- https://doi.org/10.3928/1081597X-20241002-05