Back to Search Start Over

Colorimetric and fluorescence detection of Pb 2+ by fluorescein derivative.

Authors :
Chaivisuthangkura T
Boosamund N
Asawutmangkul N
Khammee T
Jityuti B
Siangproh W
Source :
Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy [Spectrochim Acta A Mol Biomol Spectrosc] 2024 Nov 01; Vol. 327, pp. 125373. Date of Electronic Publication: 2024 Nov 01.
Publication Year :
2024
Publisher :
Ahead of Print

Abstract

A simple and low cost method for rapid detection of Pb <superscript>2+</superscript> was developed in this study using a simple fluorescent probe, biotin-4-fluorescein. The presence of Pb <superscript>2+</superscript> induced the color change of fluorescein from yellow to pink which can be detected visually by naked eyes. The color change of biotin-4-fluorescein was not observed while testing with other metal ions, such as Fe <superscript>3+</superscript> , Cu <superscript>2+</superscript> , Ca <superscript>2+</superscript> , Co <superscript>2+</superscript> and Cd <superscript>2+</superscript> , indicating the selectivity of fluorescein derivative with Pb <superscript>2+</superscript> . Moreover, the color change was observed at pH above 7.0, and the pink color got more intense when increasing pH. Adding EDTA, a chelating reagent, into the solution of biotin-4-fluorescein/Pb <superscript>2+</superscript> resulted to the rebound of the color to the original color of free biotin-4-fluorescein. The fluorescence spectra of fluorescein decreased with increasing Pb <superscript>2+</superscript> concentration, and the quenching was enhanced at higher pH. The association constant (K <subscript>a</subscript> ) of 2.00 × 10 <superscript>4</superscript>  M <superscript>-1</superscript> was calculated from the fluorescence spectra with the limit of detection (LOD) and the limit of quantitation (LOQ) of 1.38 × 10 <superscript>-5</superscript>  M (2.86 ppm) and 4.61 × 10 <superscript>-5</superscript>  M (9.55 ppm), respectively. Job's plot analysis indicated 2:1 ratio of binding interaction. Pb <superscript>2+</superscript> in untreated wastewater was quantified for 24.99 ppm using this method. This quick analysis can be beneficial for the application of lead detection in real sample solutions, such as wastewater from industrial factories.<br />Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2024 Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-3557
Volume :
327
Database :
MEDLINE
Journal :
Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy
Publication Type :
Academic Journal
Accession number :
39522228
Full Text :
https://doi.org/10.1016/j.saa.2024.125373