Percutaneous decannulation of extracorporeal membrane oxygenation using MANTA device: A real-world single-center experience.

Authors :
Milioglou I
Qian A
Salerno PRVO
Pereira GTR
Palma Dallan LA
Gray KE
Morrison M
Abu-Omar Y
Eldiasty M
Baeza C
Source :
World journal of cardiology [World J Cardiol] 2024 Oct 26; Vol. 16 (10), pp. 574-579.
Publication Year :
2024

Abstract

Background: The MANTA vascular closure device (VCD) represents a novel approach to achieving hemostasis after large-bore femoral access procedures. Numerous clinical studies have evaluated the efficacy of the MANTA device across a range of patient populations undergoing different procedures. However, there is still a paucity of data available concerning the use of MANTA devices in aiding the decannulation of venoarterial extracorporeal membrane oxygenation (VA-ECMO).<br />Aim: To present our single-center experience of utilizing the MANTA VCD in patients undergoing this procedure.<br />Methods: This single-center study included all patients undergoing percutaneous decannulation of femoral VA-ECMO using the MANTA plug-based VCD between January 2021 and October 2023 at University Hospitals Cleveland Medical Center. Inclusion criteria were adult patients who required prolonged (> 24 hours) hemodynamic support with VA-ECMO. Outcomes included all-cause mortality, hemostasis, bleeding, limb ischemia, and site infection.<br />Results: This is a retrospective cohort study of 19 patients with a mean age of 56.8 years. Twelve of them were males with a mean body mass index of 29. The most common extracorporeal membrane oxygenation indication was acute coronary syndrome complicated by cardiogenic shock at 36.8%. The mean length of intensive care unit stay for these patients was 18.8 ± 8.42 days. Seventeen out of 19 patients survived to discharge. The MANTA device was successfully deployed in 19 patients, with 10 procedures conducted at the bedside and 9 in an operating room setting. Complete hemostasis was achieved within 5 minutes of MANTA deployment in 17 out of 19 patients. In 2 patients manual compression after Manta deployment was required to achieve adequate hemostasis. Additionally, acute lower extremity ischemia was noted in two patients, necessitating endovascular interventions. No infections were reported at the site of MANTA deployment.<br />Conclusion: Overall, based on our experience and that of other centers, the MANTA VCD has proven to be a simple, safe, and effective percutaneous technique for facilitating in the OR, but most of all it opens the opportunity for bedside VA-ECMO decannulation. Post-decannulation ischemic complications are higher in this series of sick patients when compared with elective procedures like transcatheter aortic valve replacement and endovascular aneurysm repair. Additionally, operators should be mindful of the incidence of ischemic complications. Distal Doppler pulse signals should always be checked, to indicate bailout options when this occurs.<br />Competing Interests: Conflict-of-interest statement: No conflict of interest is declared by the authors of this manuscript.<br /> (©The Author(s) 2024. Published by Baishideng Publishing Group Inc. All rights reserved.)

Details

Language :
English
ISSN :
1949-8462
Volume :
16
Issue :
10
Database :
MEDLINE
Journal :
World journal of cardiology
Publication Type :
Academic Journal
Accession number :
39492973
Full Text :
https://doi.org/10.4330/wjc.v16.i10.574