Back to Search
Start Over
A selective dual-signal electrochemical paper-based device using imprinted sensors for voltammetric and impedance analysis of 4-NQO and carcinoembryonic antigen (CEA).
- Source :
-
Analytica chimica acta [Anal Chim Acta] 2024 Nov 22; Vol. 1330, pp. 343273. Date of Electronic Publication: 2024 Sep 21. - Publication Year :
- 2024
-
Abstract
- Background: Carcinoembryonic Antigen (CEA) and 4-nitroquinoline-N-oxide (4-NQO) are cancer markers that play a crucial role in tumor risk assessment and early cancer diagnosis. Therefore, it is in demand to develop a fast, accurate, simple, and cost-effective method to detect these cancer markers for quick and early stage-cancer diagnosis and treatment.<br />Results: Herein, we report a dual signaling approach for direct and indirect signal transduction of cancer biomarker binding on molecularly imprinted-electrodes integrated on an ePAD, enabling sensitive and selective quantitative analysis of 4-NQO and CEA. Multiple test zones on a single device based on artificial recognition sites using core-shell Cu-MOF@MIP were developed to create a selective "Dual-signal-ePAD". An effective and facile imprinting method on a Cu-MOF surface based on the synthesized of 4-VPBA/MAA/TRIM polymer. It resulted in a novel MIP useable as a high-performance sensing tool for the ultrasensitive and specific quantification of the target cancer biomarkers. Multiple tests consisted of voltammetric analysis of 4-NQO via oxidation of the analyte on a WE <subscript>1</subscript> , and impedance analysis of CEA via the molecular interaction with the imprinted WE <subscript>2</subscript> .<br />Significance: The proposed device provides enhanced electrochemical signal amplification due to its high conductivity, electrocatalytic activity, and the target-specific recognition sites for accurate determination of 4-NQO and CEA targets. The Dual-signal-ePAD exhibits good voltammetric and EIS response, oxidation currents of 4-NQO at -0.06 V and R <subscript>CT</subscript> of CEA, resulting in high selectivity and sensitivity with a linear response range covering the concentration range of clinical interest for both analytes. Dual-signal ePAD is a good candidate for clinical screening and POCT.<br />Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2024 Elsevier B.V. All rights reserved.)
- Subjects :
- Humans
Paper
Electrodes
Metal-Organic Frameworks chemistry
Copper chemistry
Molecular Imprinting
Limit of Detection
Biosensing Techniques
Electric Impedance
Biomarkers, Tumor analysis
Carcinoembryonic Antigen analysis
Electrochemical Techniques instrumentation
Electrochemical Techniques methods
4-Nitroquinoline-1-oxide
Subjects
Details
- Language :
- English
- ISSN :
- 1873-4324
- Volume :
- 1330
- Database :
- MEDLINE
- Journal :
- Analytica chimica acta
- Publication Type :
- Academic Journal
- Accession number :
- 39489955
- Full Text :
- https://doi.org/10.1016/j.aca.2024.343273