Back to Search Start Over

Effect of build orientation on the fabrication trueness of additively manufactured implant-supported complete arch interim fixed prostheses.

Authors :
Nejat AH
Güven ME
Çakmak G
Yilmaz B
Donmez MB
Source :
Journal of prosthodontics : official journal of the American College of Prosthodontists [J Prosthodont] 2024 Oct 28. Date of Electronic Publication: 2024 Oct 28.
Publication Year :
2024
Publisher :
Ahead of Print

Abstract

Purpose: To evaluate how build orientation affects the fabrication trueness of additively manufactured implant-supported complete arch prostheses by comparing them to subtractively manufactured high-impact polymer-based prostheses.<br />Materials and Methods: An edentulous maxillary model with four implants at canine and first molar regions bilaterally was digitized (ATOS Core 80 5MP) to design a reference implant-supported complete arch prosthesis standard tessellation language file (RF-STL). The STL file was used to manufacture prostheses additively in five different orientations according to the build platform (AM-0, 0-degree; AM-15, 15-degree; AM-30, 30-degree; AM-45, 45-degree; AM-90, 90-degree) or subtractively (SM-HIP, control) (n = 10). The prostheses were digitized with an intraoral scanner (Trios 3) to generate their STLs (TF-STL). After superimposing TF-STLs over the RF-STL with a metrology-grade analysis software program (Geomagic Control X), surface deviations at four regions (overall, occlusal, overall without occlusal, and abutments), linear deviations at each abutment site, and interimplant distance deviations (canine-to-molar, canine-to-canine, and molar-to-molar) were calculated. One-way analysis of variance and Tukey HSD tests were used for the statistical analyses (α = 0.05).<br />Results: AM-90 mostly had the highest surface deviations, while AM-0 had the lowest overall, and lowest overall without occlusal region deviations (p ≤ 0.022). SM-HIP had the lowest occlusal region deviations (p < 0.001). AM-90 had the highest linear deviations (p < 0.001). AM-15 had higher canine-to-molar deviations than SM-HIP (p = 0.042). SM-HIP had the highest canine-to-canine deviations, while AM-90 had higher deviations than AM-0 and AM-30 (p ≤ 0.026). AM-45 and AM-90 had the highest and AM-0 had the lowest molar-to-molar deviations (p ≤ 0.013).<br />Conclusions: AM-0 mostly had higher trueness and AM-90 mostly had lower trueness within tested outcomes. Additively manufactured prostheses mostly had lower canine-to-molar distances and higher molar-to-molar distances, whereas SM-HIP prostheses consistently had higher distances than the design file.<br /> (© 2024 The Author(s). Journal of Prosthodontics published by Wiley Periodicals LLC on behalf of American College of Prosthodontists.)

Details

Language :
English
ISSN :
1532-849X
Database :
MEDLINE
Journal :
Journal of prosthodontics : official journal of the American College of Prosthodontists
Publication Type :
Academic Journal
Accession number :
39468782
Full Text :
https://doi.org/10.1111/jopr.13972