Evaluating small coronary stents with dual-source photon-counting computed tomography: effect of different scan modes on image quality and performance in a phantom.

Authors :
Stein T
von Zur Muhlen C
Verloh N
Schürmann T
Krauss T
Soschynski M
Westermann D
Taron J
Can E
Schlett CL
Bamberg F
Schuppert C
Hagar MT
Source :
Diagnostic and interventional radiology (Ankara, Turkey) [Diagn Interv Radiol] 2025 Jan 01; Vol. 31 (1), pp. 29-38. Date of Electronic Publication: 2024 Oct 21.
Publication Year :
2025

Abstract

Purpose: The study aimed to assess the feasibility and image quality of dual-source photon-counting detector computed tomography (PCD-CT) in evaluating small-sized coronary artery stents with respect to different acquisition modes in a phantom model.<br />Methods: Utilizing a phantom setup mimicking the average patient's water-equivalent diameter, we examined six distinct coronary stents inflated in a silicon tube, with stent sizes ranging from 2.0 to 3.5 mm, applying four different CT acquisition modes of a dual-source PCD-CT scanner: "high-pitch," "sequential," "spiral" (each with collimation of 144 × 0.4 mm and full spectral information), and "ultra-high-resolution (UHR)" (collimation of 120 × 0.2 mm and no spectral information). Image quality and diagnostic confidence were assessed using subjective measures, including a 4-point visual grading scale (4 = excellent; 1 = non-diagnostic) utilized by two independent radiologists, and objective measures, including the full width at half maximum (FWHM).<br />Results: A total of 24 scans were acquired, and all were included in the analysis. Among all CT acquisition modes, the highest image quality was obtained for the UHR mode [median score: 4 (interquartile range (IQR): 3.67-4.00)] ( P = 0.0015, with 37.5% rated as "excellent"), followed by the sequential mode [median score: 3.5 (IQR: 2.84-4.00)], P = 0.0326 and the spiral mode [median score: 3.0 (IQR: 2.53-3.47), P > 0.05]. The lowest image quality was observed for the high-pitch mode [median score: 2 (IQR: 1- 3), P = 0.028]. Similarly, diagnostic confidence for evaluating stent patency was highest for UHR and lowest for high-pitch ( P < 0.001, respectively). Measurement of stent dimensions was accurate for all acquisition modes, with the UHR mode showing highest robustness (FWHM for sequential: 0.926 ± 0.061 vs. high-pitch: 0.990 ± 0.083 vs. spiral: 0.962 ± 0.085 vs. UHR: 0.941 ± 0.036, P = non-significant, respectively).<br />Conclusion: Assessing small-sized coronary stents using PCD-CT technology is feasible. The UHR mode offers superior image quality and diagnostic confidence, while all modes show consistent and accurate measurements.<br />Clinical Significance: These findings highlight the potential of PCD-CT technology, particularly the UHR mode, to enhance non-invasive coronary stent evaluation. Confirmatory research is necessary to influence the guidelines, which recommend cardiac CT only for stents of 3 mm or larger.<br />Competing Interests: Fabian Bamberg Siemens Healthineers AG (unrestricted research grant, speaker’s bureau), Christopher L. Schlett Siemens Healthineers AG (speaker’s bureau), Muhammad Taha Hagar Siemens Healthineers AG (speaker‘s bureau). Other authors have nothing to disclose.

Details

Language :
English
ISSN :
1305-3612
Volume :
31
Issue :
1
Database :
MEDLINE
Journal :
Diagnostic and interventional radiology (Ankara, Turkey)
Publication Type :
Academic Journal
Accession number :
39463047
Full Text :
https://doi.org/10.4274/dir.2024.242893