Back to Search
Start Over
The impact of large aneurysm diameter on the outcomes of thoracoabdominal aneurysm repair by fenestrated and branched endografts.
- Source :
-
European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery [Eur J Cardiothorac Surg] 2024 Nov 04; Vol. 66 (5). - Publication Year :
- 2024
-
Abstract
- Objectives: Aim of the study was to analyse the impact of preoperative thoracoabdominal aneurysm diameter on the outcomes of fenestrated/branched endografting.<br />Methods: Patients who underwent endovascular thoracoabdominal repair at 2 European centres (2011-2021) were analysed. Median diameter was calculated; the third quartile was considered a cut-off. Outcomes were compared in 2 groups based on the diameter value. Primary endpoints were technical success, spinal cord ischaemia and 30-day/in-hospital mortality. Survival, freedom from reintervention and target visceral vessels instability were follow-up outcomes.<br />Results: Out of 247 thoracoabdominal aortic aneurysms, the median diameter was 65 mm, first quartile was 57 mm; third quartile was 80 mm, set as cut-off value. Fifty-nine (24%) patients had diameter ≥80 mm. Custom-made and off-the-shelf branched endograft were used in 160 (65%) and 87 (35%), respectively. Technical success was 93% (<80 mm: 91% vs ≥80 mm: 94%; P = 0.47). Twenty-three (9%) patients had spinal injury (<80 mm: 7% vs ≥80mm: 17%; P = 0.03). Twenty-two (9%) patients died within 30-day/in-hospital (<80 mm: 7% vs ≥80 mm: 15%; P = 0.06). Multivariate analysis did not report preoperative diameter ≥80 mm as significant risk factor for primary endpoints. The median follow-up was 13 (interquartile range: 2-37) months and at 3-year survival and freedom from reintervention rates were 65% and 62%, respectively. After univariate and multivariate analyses, preoperative diameter ≥80 mm was considered an independent risk factor for reinterventions [hazard ratio (HR): 1.9; 95% confidence interval (CI) 1.1-3.6; P = 0.04], and for target visceral vessels instability (HR: 3.1; 95% CI: 1.3-5.1; P = 0.04), occurred in 45 (18%) cases. However, after competing risk methods, preoperative diameter did not show significance for follow-up results.<br />Conclusions: A preoperative thoracoabdominal aortic aneurysm diameter >80 mm has not had a direct impact on early technical and clinical outcomes. A diameter≥80 mm is considered risk factor for reinterventions and target vessels instability is considered separately during follow-up.<br /> (© The Author(s) 2024. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery.)
- Subjects :
- Humans
Male
Female
Aged
Treatment Outcome
Retrospective Studies
Postoperative Complications epidemiology
Hospital Mortality
Prosthesis Design
Middle Aged
Aged, 80 and over
Risk Factors
Aortic Aneurysm, Thoracic surgery
Aortic Aneurysm, Thoracic mortality
Endovascular Procedures methods
Endovascular Procedures adverse effects
Blood Vessel Prosthesis Implantation methods
Blood Vessel Prosthesis Implantation adverse effects
Blood Vessel Prosthesis Implantation mortality
Blood Vessel Prosthesis
Subjects
Details
- Language :
- English
- ISSN :
- 1873-734X
- Volume :
- 66
- Issue :
- 5
- Database :
- MEDLINE
- Journal :
- European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery
- Publication Type :
- Academic Journal
- Accession number :
- 39447039
- Full Text :
- https://doi.org/10.1093/ejcts/ezae387