Back to Search
Start Over
Highly efficient image navigator based 3D whole-heart cardiac MRA at 0.55T.
- Source :
-
Magnetic resonance in medicine [Magn Reson Med] 2025 Feb; Vol. 93 (2), pp. 689-698. Date of Electronic Publication: 2024 Oct 16. - Publication Year :
- 2025
-
Abstract
- Purpose: To develop and evaluate a highly efficient free-breathing and contrast-agent-free three-dimensional (3D) whole-heart Cardiac Magnetic Resonance Angiography (CMRA) sequence at 0.55T.<br />Methods: Free-breathing whole-heart CMRA has been previously proposed at 1.5 and 3T. Direct application of this sequence to 0.55T is not possible due to changes in the magnetic properties of the tissues. To enable free-breathing CMRA at 0.55T, pulse sequence design and acquisition parameters of a previously proposed whole-heart CMRA framework are optimized via Bloch simulations. Image navigators (iNAVs) are used to enable nonrigid respiratory motion-correction and 100% respiratory scan efficiency. Patch-based low-rank denoising is employed to accelerate the scan and account for the reduced signal-to-noise ratio at 0.55T. The proposed approach was evaluated on 11 healthy subjects. Image quality was assessed by a clinical expert (1: poor to 5: excellent) for all intrapericardiac structures. Quantitative evaluation was performed by assessing the vessel sharpness of the proximal right coronary artery (RCA).<br />Results: Optimization resulted in an imaging flip angle of 11 0 ∘ $$ 11{0}^{\circ } $$ , fat saturation flip angle of 18 0 ∘ $$ 18{0}^{\circ } $$ , and six k-space lines for iNAV encoding. The relevant cardiac structures and main coronary arteries were visible in all subjects, with excellent image quality (mean 4 . 9 / 5 . 0 $$ 4.9/5.0 $$ ) and minimal artifacts (mean 4 . 9 / 5 . 0 $$ 4.9/5.0 $$ ), with RCA vessel sharpness ( 50 . 3 % ± 9 . 8 % $$ 50.3\%\pm 9.8\% $$ ) comparable to previous studies at 1.5T.<br />Conclusion: The proposed approach enables 3D whole-heart CMRA at 0.55T in a 6-min scan ( 5 . 9 ± 0 . 7 min $$ 5.9\pm 0.7\;\min $$ ), providing excellent image quality, minimal artifacts, and comparable vessel sharpness to previous 1.5T studies. Future work will include the evaluation of the proposed approach in patients with cardiovascular disease.<br /> (© 2024 The Author(s). Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.)
- Subjects :
- Humans
Male
Adult
Algorithms
Female
Coronary Vessels diagnostic imaging
Signal-To-Noise Ratio
Image Processing, Computer-Assisted methods
Reproducibility of Results
Image Interpretation, Computer-Assisted methods
Image Enhancement methods
Magnetic Resonance Angiography methods
Imaging, Three-Dimensional methods
Heart diagnostic imaging
Subjects
Details
- Language :
- English
- ISSN :
- 1522-2594
- Volume :
- 93
- Issue :
- 2
- Database :
- MEDLINE
- Journal :
- Magnetic resonance in medicine
- Publication Type :
- Academic Journal
- Accession number :
- 39415543
- Full Text :
- https://doi.org/10.1002/mrm.30316