Back to Search
Start Over
Prediction of Late Proximal Endoleak Risk after EVAR by Preoperative Estimation of Endograft/Aortic Neck Apposition Surface.
- Source :
-
Annals of vascular surgery [Ann Vasc Surg] 2025 Jan; Vol. 110 (Pt B), pp. 440-449. Date of Electronic Publication: 2024 Oct 15. - Publication Year :
- 2025
-
Abstract
- Background: The aim of this study was to evaluate a new measurement tool for the preoperative computed tomography (CT) scan to estimate the endograft apposition surface on the proximal aortic neck of the aneurysm that would predict the risk of late type IA endoleak (EL1A).<br />Methods: From databases of 4 high-volume centers between 2004 and 2020, all patients who underwent Endovascular Aneuruysm Repair (EVAR) with the possibility of analyzing pre and post-EVAR scans and who presented late (>2 years) EL1A in follow-up were included retrospectively (EL1A group). A control group of randomly selected EL1A-free patients were included (control group) and followed-up beyond 4 years. The measurement tool (Endosize, Therenva) was used to model a virtual cylinder constrained by the centreline whose diameter was determined from the diameter of the implanted endograft. The apposition surface was calculated by determining the areas of the virtual cylinder mesh outside the mesh of the neighboring portion of the segmented aorta by an intersection calculation of surface normals. This apposition surface and the usual anatomical data of the proximal neck were compared between the groups with univariate and multivariate analyses. Intra and interobserver variability in the measurement of apposition surface was analyzed using the intraclass correlation coefficient (ICC) and the method of Bland and Altman.<br />Results: Sixty-six comparable patients were included as follows: 33 in the EL1A group and 33 in the control group. The mean time to EL1A onset was 50.2 ± 24.6 months in the EL1A group, and the mean follow-up time was 79.8 ± 26.8 months in the control group. In univariate analysis, only the endograft apposition surface ratio on the proximal neck was significantly lower in the EL1A group compared with the control group (50.3% vs. 75.5%; P < 0.0001). There was no significant difference in classic anatomical neck characteristics. There was no difference in proximal endograft oversizing or in the length from the lowest renal artery to the beginning of the covered portion of the endograft. In multivariate analysis, only the apposition surface ratio was independently correlated with the presence of EL1A (P < 0.0001). The estimation of the intra and interobserver variability indicates excellent reliability (ICC = 0.992; ICC = 0.956).<br />Conclusions: The method estimating the preoperative endograft apposition surface on the proximal aortic neck appears to be a reliable measuring technique in predicting the risk of occurrence of late EL1A after EVAR.<br /> (Copyright © 2024. Published by Elsevier Inc.)
- Subjects :
- Aged
Aged, 80 and over
Female
Humans
Male
Databases, Factual
Predictive Value of Tests
Reproducibility of Results
Retrospective Studies
Risk Assessment
Risk Factors
Stents
Time Factors
Treatment Outcome
Aortic Aneurysm, Abdominal surgery
Aortic Aneurysm, Abdominal diagnostic imaging
Aortography
Blood Vessel Prosthesis
Blood Vessel Prosthesis Implantation adverse effects
Blood Vessel Prosthesis Implantation instrumentation
Computed Tomography Angiography
Endoleak etiology
Endoleak diagnostic imaging
Endovascular Procedures adverse effects
Endovascular Procedures instrumentation
Subjects
Details
- Language :
- English
- ISSN :
- 1615-5947
- Volume :
- 110
- Issue :
- Pt B
- Database :
- MEDLINE
- Journal :
- Annals of vascular surgery
- Publication Type :
- Academic Journal
- Accession number :
- 39414000
- Full Text :
- https://doi.org/10.1016/j.avsg.2024.09.050