Back to Search
Start Over
Comparison of Ultrathin- Versus Thin-Strut Stents in Patients With High Bleeding Risk PCI: Results From the COMPARE 60/80 HBR Trial: An Open-Label, Randomized, Controlled Trial.
- Source :
-
Circulation. Cardiovascular interventions [Circ Cardiovasc Interv] 2024 Oct; Vol. 17 (10), pp. e014042. Date of Electronic Publication: 2024 Oct 01. - Publication Year :
- 2024
-
Abstract
- Background: No randomized data exist on ultrathin-strut stents in patients at high bleeding risk (HBR) undergoing an abbreviated dual antiplatelet therapy after coronary stenting. The aim of this study was to compare the safety and effectiveness of the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent with the thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent in patients at HBR with abbreviated dual antiplatelet therapy after stenting.<br />Methods: In the investigator-initiated, randomized, open-label COMPARE 60/80 HBR trial (Comparison of the Supraflex Cruz 60 Micron Stent Strut Versus the Ultimaster Tansei 80 Micron Stent Strut in HBR Percutaneous Coronary Intervention Population), 741 patients at HBR according to the Academic Research Consortium HBR criteria were randomized to receive either the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent or thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent. Dual antiplatelet therapy was recommended according to the applicable guidelines and trial data for patients at HBR. The primary outcome was net adverse clinical events, the composite of cardiovascular death, myocardial infarction, target vessel revascularization, stroke, and major bleeding, and was powered for noninferiority with an absolute margin of 4.0% at 1-sided 2.5% alpha.<br />Results: Between September 2020 and August 2022, 371 patients were randomized to the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent and 370 patients to the thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent at 11 sites in the Netherlands. At 1 year, the primary outcome was observed in 56 (15.4%) patients in the ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent group and 61 (17.1%) in the thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent group (risk difference, -1.65%; upper boundary of the 1-sided 95% CI, 3.74; P =0.02 for noninferiority at a 0.025 significance level and P =0.55 for 2-sided superiority at a 0.05 significance level).<br />Conclusions: Among patients at HBR with abbreviated dual antiplatelet therapy post-stenting, the use of an ultrathin-strut biodegradable-polymer sirolimus-eluting Supraflex Cruz stent was noninferior compared with the use of a thin-strut biodegradable-polymer sirolimus-eluting Ultimaster Tansei stent.<br />Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT04500912.<br />Competing Interests: Dr Smits reports personal fees from Terumo and Abiomed, institutional grants and personal fees from Abbott Vascular and Microport, and institutional grants from SMT. Dr Hofma reports an institutional grant from Terumo. Dr Oemrawsingh reports speaker fees from Abbott Vascular and Philips. Dr Paradies reports speaker fees from Boston Scientific and Abbott Vascular and institutional grants from Abbott Vascular. The other authors report no conflicts.
- Subjects :
- Humans
Male
Female
Aged
Middle Aged
Treatment Outcome
Risk Factors
Risk Assessment
Time Factors
Drug-Eluting Stents
Percutaneous Coronary Intervention adverse effects
Percutaneous Coronary Intervention instrumentation
Percutaneous Coronary Intervention mortality
Sirolimus administration & dosage
Sirolimus adverse effects
Prosthesis Design
Platelet Aggregation Inhibitors administration & dosage
Platelet Aggregation Inhibitors adverse effects
Hemorrhage chemically induced
Dual Anti-Platelet Therapy adverse effects
Coronary Artery Disease therapy
Coronary Artery Disease mortality
Coronary Artery Disease diagnostic imaging
Subjects
Details
- Language :
- English
- ISSN :
- 1941-7632
- Volume :
- 17
- Issue :
- 10
- Database :
- MEDLINE
- Journal :
- Circulation. Cardiovascular interventions
- Publication Type :
- Academic Journal
- Accession number :
- 39351676
- Full Text :
- https://doi.org/10.1161/CIRCINTERVENTIONS.123.014042