Back to Search Start Over

Autologous serum eye drops for patients with dry eye disease: a systematic review and meta-analysis of randomized controlled trials.

Authors :
He CZ
Zeng ZJ
Liu JQ
Qiu Q
He Y
Source :
Frontiers in medicine [Front Med (Lausanne)] 2024 Sep 13; Vol. 11, pp. 1430785. Date of Electronic Publication: 2024 Sep 13 (Print Publication: 2024).
Publication Year :
2024

Abstract

Background: Dry eye disease (DED) is highly prevalent worldwide, leading to increased medical costs, economic burdens on families and society, and a diminished quality of life for patients. The utilization of autologous serum eye drops (ASEDs) for the treatment of DED is progressively rising.<br />Objective: To further evaluate the efficacy and safety of ASEDs in the treatment of DED.<br />Methods: A thorough search for randomized controlled trials (RCTs) was conducted across eight databases, including PubMed, EMBASE, the Cochrane Library, Web of Science, China National Knowledge Infrastructure, Wanfang, SinoMed, and VIP. This search encompassed the inception of each database up to April 1, 2024, with a specific focus on identifying RCTs evaluating the efficacy and safety of ASEDs for the treatment of DED. Data analysis was conducted utilizing Stata 15.0 software and the Cochrane Risk of Bias Assessment Tool was utilized to appraise the literature's quality.<br />Results: The study encompassed 12 RCTs. In comparison to the use of artificial tears (AT), patients diagnosed with DED who utilized ASEDs displayed elevated the Schirmer test (ST) scores [WMD = 2.35, 95% CI (1.45, 3.24), p < 0.001] and tear-film breakup time (TBUT) scores [WMD = 2.83, 95% CI (2.27, 3.39), p < 0.001], decreased Corneal fluorescence staining (CFS) scores [SMD = -2.11, 95% CI (-3.07, -1.15), p < 0.001] and the Ocular Surface Disease Index (OSDI) scores [WMD = -10.54, 95% CI (-13.31, -7.77), p < 0.001], and experienced a reduced frequency of adverse events [RR = 0.36, 95% CI (0.13, 0.99), p = 0.048].<br />Conclusion: In this study, ASEDs had been shown to enhance tear secretion, extend tear film break-up time, mitigate corneal epithelial damage, ameliorate OSDI scores, and exhibit greater safety compared to AT.<br />Competing Interests: The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.<br /> (Copyright © 2024 He, Zeng, Liu, Qiu and He.)

Details

Language :
English
ISSN :
2296-858X
Volume :
11
Database :
MEDLINE
Journal :
Frontiers in medicine
Publication Type :
Academic Journal
Accession number :
39346942
Full Text :
https://doi.org/10.3389/fmed.2024.1430785