Back to Search Start Over

Enhanced antifouling and anti-swarming properties poly (sulfobetaine methacrylate-co-2-hydroxy-3-phenoxypropyl acrylate) hydrogel coatings for urinary catheters.

Authors :
Yao C
Teng X
Sun D
McCoy CP
Zhang S
Source :
Colloids and surfaces. B, Biointerfaces [Colloids Surf B Biointerfaces] 2025 Jan; Vol. 245, pp. 114277. Date of Electronic Publication: 2024 Sep 27.
Publication Year :
2025

Abstract

Catheter-associated urinary tract infection (CAUTI) remains an unsolved challenge to date, particularly with the emergence and rapid spread of antimicrobial-resistant bacterial pathogens. Despite extensive research, a catheter coating that can offer intrinsic resistance to host protein deposition, bacterial biofilm formation, and swarming is still urgently required. Zwitterionic hydrogel coatings due to their superior lubricity and antifouling properties represent a promising candidate, but their weak mechanical stability in water and poor resistance to bacterial swarming migration limit their application in urinary catheters for infection control. In this research, we describe the fabrication of a multifunctional catheter coating by copolymerizing zwitterionic sulfobetaine methacrylate (SBMA) polymers and a swarming inhibitor material, 2-hydroxy-3-phenoxypropyl acrylate (HPA). The introduction of polyHPA (PHPA) effectively impeded the uncontrolled swelling behavior of the zwitterionic PSBMA hydrogel, resulting in enhanced mechanical stability. Moreover, the copolymer coating retains the antifouling and anti-swarming properties of the homopolymers when challenged with fibrinogen, Escherichia coli, and Proteus mirabilis. The HPA content significantly correlated with its anti-adhesion activity against fibrinogen and biofilm, and the coating with an SBMA: HPA monomer feed molar ratio of 4:1 showed the best antifouling activity, reducing fibrinogen deposition by about 40 % and biofilm coverage by around fourfold compared to the uncoated polydimethylsiloxane (PDMS) surface. Furthermore, the copolymer coating also exhibited no cytotoxicity, suggesting it as a promising catheter coating for preventing CAUTI.<br />Competing Interests: Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2024 The Authors. Published by Elsevier B.V. All rights reserved.)

Details

Language :
English
ISSN :
1873-4367
Volume :
245
Database :
MEDLINE
Journal :
Colloids and surfaces. B, Biointerfaces
Publication Type :
Academic Journal
Accession number :
39342727
Full Text :
https://doi.org/10.1016/j.colsurfb.2024.114277