Background: Rotational malalignment after operative fracture treatment of the lower extremity may be associated with increased pain and functional impairment. Despite its clinical relevance, there are no uniform management guidelines. The aim of this scoping review is to provide an overview of all available evidence to diagnose and treat rotational deformities of the lower extremity following operative fracture treatment.<br />Methods: This scoping review was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. A literature search was carried out on 22 August 2023 by two independent reviewers in the Pubmed (MEDLINE), Embase, Web of Science, and Cochrane library databases. The search strategy was developed with the assistance of a biomedical information specialist. The main search terms were tibial and femoral malrotations. Disagreements were resolved through discussion with a third reviewer.<br />Results: After screening and quality assessment of 3929 unique identified records, 50 articles were included for qualitative synthesis. Most studies were retrospective case reports or case series. Thirty studies focused on the femur, 11 on the tibia and nine included both femur and tibia. Most of the included studies presented cases where malrotation was associated with other limb deformities. Only 18 studies focused solely on the treatment of malrotation of the lower extremities after operative fracture treatment. Regarding diagnosis, bilateral CT-scans were used in 34 studies. Regarding treatment, external fixation was used in two studies, internal fixation (either intramedullary nail or plate) in 45 studies, and in three studies the authors used both. Overall, revision surgery resulted in good clinical outcomes with low complication rates.<br />Conclusion: This scoping review reveals that rotational malalignment following operative treatment of lower extremity fractures remains an important complication. Although it occurs frequently and is associated with severe disability for the patient, standardized guidelines regarding the terminology, diagnosis, indications for intervention and treatment are lacking. CT-scan is the most used diagnostic modality in daily clinical practice. Revision surgery, using diverse operative techniques, demonstrated positive results, significantly alleviating patient complaints with few complications. Nevertheless, an international consensus regarding the optimal management pathway is needed, and future prospective clinical studies seem therefore necessary.<br />Competing Interests: Declaration of competing interest All authors declare no conflict of interest with respect to the preparation and writing of this article.<br /> (Copyright © 2024 Elsevier Ltd. All rights reserved.)

Details

Language :
English
ISSN :
1879-0267
Volume :
55
Issue :
11
Database :
MEDLINE
Journal :
Injury
Publication Type :
Academic Journal
Accession number :
39341048
Full Text :
https://doi.org/10.1016/j.injury.2024.111903