Back to Search Start Over

Diagnostic Accuracy of Five Molecular Assays for the Detection of Dengue Virus.

Authors :
Scarpaleggia M
Garzillo G
Lucente M
Fraccalvieri C
Randazzo N
Massaro E
Galano B
Ricucci V
Bruzzone B
Domnich A
Source :
Medicina (Kaunas, Lithuania) [Medicina (Kaunas)] 2024 Sep 23; Vol. 60 (9). Date of Electronic Publication: 2024 Sep 23.
Publication Year :
2024

Abstract

Background and Objectives : The steady spread of dengue virus (DENV) poses a profound public health threat worldwide. Reverse transcription real-time polymerase chain reaction (RT2-PCR) has been increasingly recognized as a reference method for the diagnosis of acute dengue infection. The goal of this study was to assess the diagnostic accuracy of five different RT2-PCR kits for the detection of DENV in a historically processed set of sera samples. Materials and Methods : In this retrospective study, 25 sera samples from routinely processed unique adult patients with a known DENV status (previously tested in both molecular and serological assays) were tested in parallel using four conventional (RealStar Dengue PCR Kit 3.0, Clonit'ngo Zika, Dengue & Chikungunya, BioPerfectus Zika Virus/Dengue Virus/Chikungunya Virus Real Time PCR Kit and Novaplex Tropical fever virus) and one sample-to-result (STANDARD M10 Arbovirus Panel) RT2-PCR assays. Additionally, an end-point dilution analysis was conducted in quintuplicate on six serial dilutions of an RNA preparation obtained from a culture-grown DENV serotype 1 strain for a total of 150 tests. Results : The overall accuracy of the evaluated tests ranged from 84% to 100%. In particular, the sensitivity of three conventional RT2-PCR assays (RealStar, Clonit'ngo and Novaplex) was 100% (95% CI: 79.6-100%), while it was lower (73.3%; 95% CI: 48.1-89.1%) for the BioPerfectus kit. The sample-to-result STANDARD M10 panel performed comparatively well, showing a sensitivity of 92.9% (95% CI: 68.5-98.7%). No false positive results were registered in any assay. The end-point dilution analysis suggested that the RealStar kit had the lowest limit of detection. Conclusions : Available RT2-PCR kits for the detection of DENV are highly specific and generally sensitive and, therefore, their implementation in diagnostic pathways is advisable.

Details

Language :
English
ISSN :
1648-9144
Volume :
60
Issue :
9
Database :
MEDLINE
Journal :
Medicina (Kaunas, Lithuania)
Publication Type :
Academic Journal
Accession number :
39336598
Full Text :
https://doi.org/10.3390/medicina60091557