Impact of occluder device configurations in in-silico left atrial hemodynamics for the analysis of device-related thrombus.

Authors :
Albors C
Mill J
Olivares AL
Iriart X
Cochet H
Camara O
Source :
PLoS computational biology [PLoS Comput Biol] 2024 Sep 26; Vol. 20 (9), pp. e1011546. Date of Electronic Publication: 2024 Sep 26 (Print Publication: 2024).
Publication Year :
2024

Abstract

Left atrial appendage occlusion devices (LAAO) are a feasible alternative for non-valvular atrial fibrillation (AF) patients at high risk of thromboembolic stroke and contraindication to antithrombotic therapies. However, optimal LAAO device configurations (i.e., size, type, location) remain unstandardized due to the large anatomical variability of the left atrial appendage (LAA) morphology, leading to a 4-6% incidence of device-related thrombus (DRT). In-silico simulations have the potential to assess DRT risk and identify the key factors, such as suboptimal device positioning. This work presents fluid simulation results computed on 20 patient-specific left atrial geometries, analysing different commercially available LAAO occluders, including plug-type and pacifier-type devices. In addition, we explored two distinct device positions: 1) the real post-LAAO intervention configuration derived from follow-up imaging; and 2) one covering the pulmonary ridge if it was not achieved during the implantation (13 out of 20). In total, 33 different configurations were analysed. In-silico indices indicating high risk of DRT (e.g., low blood flow velocities and flow complexity around the device) were combined with particle deposition analysis based on a discrete phase model. The obtained results revealed that covering the pulmonary ridge with the LAAO device may be one of the key factors to prevent DRT, resulting in higher velocities and reduced flow recirculations (e.g., mean velocities of 0.183 ± 0.12 m/s and 0.236 ± 0.16 m/s for uncovered versus covered positions in DRT patients). Moreover, disk-based devices exhibited enhanced adaptability to various LAA morphologies and, generally, demonstrated a lower risk of abnormal events after LAAO implantation.<br />Competing Interests: The authors have declared that no competing interests exist.<br /> (Copyright: © 2024 Albors et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.)

Details

Language :
English
ISSN :
1553-7358
Volume :
20
Issue :
9
Database :
MEDLINE
Journal :
PLoS computational biology
Publication Type :
Academic Journal
Accession number :
39325818
Full Text :
https://doi.org/10.1371/journal.pcbi.1011546