Back to Search Start Over

BP-diff: a conditional diffusion model for cuffless continuous BP waveform estimation using U-Net.

Authors :
Liu Y
Yu J
Mou H
Source :
Physiological measurement [Physiol Meas] 2024 Oct 14; Vol. 45 (10). Date of Electronic Publication: 2024 Oct 14.
Publication Year :
2024

Abstract

Objective. Continuous monitoring of blood pressure (BP) is crucial for daily healthcare. Although invasive methods provide accurate continuous BP measurements, they are not suitable for routine use. Photoplethysmography (PPG), a non-invasive technique that detects changes in blood volume within the microcirculation using light, shows promise for BP measurement. The primary goal of this study is to develop a novel cuffless method based on PPG for accurately estimating continuous BP. Approach. We introduce BP-Diff, an end-to-end method for cuffless continuous BP waveform estimation utilizing a conditional diffusion probability model combined with a U-Net architecture. This approach takes advantage of the stochastic properties of diffusion models and the strong feature representation capabilities of U-Net. It integrates the continuous BP waveform as the initial status and uses the PPG signal and its derivatives as conditions to guide the training and sampling process. Main results. BP-Diff was evaluated using both uncalibrated and calibrated schemes. The results indicate that, when uncalibrated, BP-Diff can accurately track BP dynamics, including peak and valley positions, as well as timing. After calibration, BP-Diff achieved highly accurate BP estimations. The mean absolute error of the estimated BP waveforms, along with the systolic BP, diastolic BP, and mean arterial pressure from the calibrated BP-Diff model, were 2.99 mmHg, 2.6 mmHg, 1.4 mmHg, and 1.44 mmHg, respectively. Consistency tests, including Bland-Altman analysis and Pearson correlation, confirmed its high reliability compared to reference BP. BP-Diff meets the American Association for Medical Instrumentation standards and has achieved a Grade A from the British Hypertension Society. Significance. This study utilizes PPG signals to develop a novel cuffless continuous BP measurement method, demonstrating superiority over existing approaches. The method is suitable for integration into wearable devices, providing a practical solution for continuous BP monitoring in everyday healthcare.<br /> (© 2024 Institute of Physics and Engineering in Medicine. All rights, including for text and data mining, AI training, and similar technologies, are reserved.)

Details

Language :
English
ISSN :
1361-6579
Volume :
45
Issue :
10
Database :
MEDLINE
Journal :
Physiological measurement
Publication Type :
Academic Journal
Accession number :
39321963
Full Text :
https://doi.org/10.1088/1361-6579/ad7fcc