Back to Search
Start Over
Development of amphiphilic hypercrosslinked porous polymers for magnetic extraction of multiple environmental pollutants in water.
- Source :
-
Journal of chromatography. A [J Chromatogr A] 2024 Nov 08; Vol. 1736, pp. 465381. Date of Electronic Publication: 2024 Sep 24. - Publication Year :
- 2024
-
Abstract
- Under the principle of similar compatibility, researchers have developed various polarity extractants corresponding to a class of chemicals. Separating different polarities chemicals with one extractant effectively has become a novel research trend in separation science. Given the complexity of environmental sample matrices and the significant differences in polarity and solubility of various compounds, the introduction of hydrophilic groups to hydrophobic material skeletons can lead to sorbents with hydrophilic-lipophilic balance (HLB) property and thus improve their extraction performance for substances with different polarities. In this work, a hypercrosslinked polymer (HCP <subscript>Pz-TPB</subscript> ), designated as HLB, was synthesized by incorporating polar pyrazine and nonpolar triphenylbenzene molecules within each other. Subsequently, a core-shell magnetic composite material was obtained by encapsulating magnetic Fe <subscript>3</subscript> O <subscript>4</subscript> nanoparticles in HCP <subscript>Pz-TPB</subscript> . The material was applied as an adsorbent for magnetic solid phase extraction (MSPE) and combined with a high-performance liquid chromatography-photodiode array detector (HPLC-PDA) to enrich, separate, and detect seven polar contaminants in environmental water samples. The proposed approach, Fe <subscript>3</subscript> O <subscript>4</subscript> @SiO <subscript>2</subscript> @HCP <subscript>Pz-TPB</subscript> -MSPE-HPLC-PDA, is characterized by its outstanding high sensitivity, low detection limits, wide linear range, and good reproducibility. The method demonstrated satisfactory linearity in the range of 0.05-2 μg mL <superscript>-1</superscript> with R <superscript>2</superscript> values between 0.9969 and 0.9997; the limits of detection (LOD) were observed to be within the range of 0.0019-0.016 μg L <superscript>-1</superscript> , and limits of quantification (LOQ) was observed to be within the range of 0.0064-0.054 μg L <superscript>-1</superscript> range with good precision. The recoveries of the different contaminants in the environmental samples ranged from 83.61 to 116.46% (RSD≤10.56, n = 5). The new hydrophilic-lipophilic balance extractant is highly efficient, sensitive, and precise for extracting different polar pollutants. The findings demonstrate that the Fe <subscript>3</subscript> O <subscript>4</subscript> @SiO <subscript>2</subscript> @HCP <subscript>Pz-TPB</subscript> display a remarkable affinity for multiple targets, driven by complex interactions including multi-stackings and hydrogen bonding as a sorbent. The synthesized Fe <subscript>3</subscript> O <subscript>4</subscript> @SiO <subscript>2</subscript> @HCP <subscript>Pz-TPB</subscript> may be employed in diverse applications, including extraction, removal, and determination of diverse trace multi-target analytes in complex media.<br />Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2024 Elsevier B.V. All rights reserved.)
- Subjects :
- Chromatography, High Pressure Liquid methods
Porosity
Magnetite Nanoparticles chemistry
Adsorption
Reproducibility of Results
Silicon Dioxide chemistry
Water Pollutants, Chemical analysis
Water Pollutants, Chemical isolation & purification
Water Pollutants, Chemical chemistry
Solid Phase Extraction methods
Polymers chemistry
Hydrophobic and Hydrophilic Interactions
Limit of Detection
Subjects
Details
- Language :
- English
- ISSN :
- 1873-3778
- Volume :
- 1736
- Database :
- MEDLINE
- Journal :
- Journal of chromatography. A
- Publication Type :
- Academic Journal
- Accession number :
- 39321754
- Full Text :
- https://doi.org/10.1016/j.chroma.2024.465381