Back to Search Start Over

Electrochemical impedance spectroscopy unmasks high-risk atherosclerotic features in human coronary artery disease.

Authors :
Chen M
Suwannaphoom K
Sanaiha Y
Luo Y
Benharash P
Fishbein MC
Packard RRS
Source :
FASEB journal : official publication of the Federation of American Societies for Experimental Biology [FASEB J] 2024 Sep 30; Vol. 38 (18), pp. e70069.
Publication Year :
2024

Abstract

Coronary plaque rupture remains the prominent mechanism of myocardial infarction. Accurate identification of rupture-prone plaque may improve clinical management. This study assessed the discriminatory performance of electrochemical impedance spectroscopy (EIS) in human cardiac explants to detect high-risk atherosclerotic features that portend rupture risk. In this single-center, prospective study, n = 26 cardiac explants were collected for EIS interrogation of the three major coronary arteries. Vessels in which advancement of the EIS catheter without iatrogenic plaque disruption was rendered impossible were not assessed. N = 61 vessels underwent EIS measurement and histological analyses. Plaques were dichotomized according to previously established high rupture-risk parameter thresholds. Diagnostic performance was determined via receiver operating characteristic areas-under-the-curve (AUC). Necrotic cores were identified in n = 19 vessels (median area 1.53 mm <superscript>2</superscript> ) with a median fibrous cap thickness of 62 μm. Impedance was significantly greater in plaques with necrotic core area ≥1.75 mm <superscript>2</superscript> versus <1.75 mm <superscript>2</superscript> (19.8 ± 4.4 kΩ vs. 7.2 ± 1.0 kΩ, p = .019), fibrous cap thickness ≤65 μm versus >65 μm (19.1 ± 3.5 kΩ vs. 6.5 ± 0.9 kΩ, p = .004), and ≥20 macrophages per 0.3 mm-diameter high-power field (HPF) versus <20 macrophages per HPF (19.8 ± 4.1 kΩ vs. 10.2 ± 0.9 kΩ, p = .002). Impedance identified necrotic core area ≥1.75 mm <superscript>2</superscript> , fibrous cap thickness ≤65 μm, and ≥20 macrophages per HPF with AUCs of 0.889 (95% CI: 0.716-1.000) (p = .013), 0.852 (0.646-1.000) (p = .025), and 0.835 (0.577-1.000) (p = .028), respectively. Further, phase delay discriminated severe stenosis (≥70%) with an AUC of 0.767 (0.573-0.962) (p = .035). EIS discriminates high-risk atherosclerotic features that portend plaque rupture in human coronary artery disease and may serve as a complementary modality for angiography-guided atherosclerosis evaluation.<br /> (© 2024 Federation of American Societies for Experimental Biology.)

Details

Language :
English
ISSN :
1530-6860
Volume :
38
Issue :
18
Database :
MEDLINE
Journal :
FASEB journal : official publication of the Federation of American Societies for Experimental Biology
Publication Type :
Academic Journal
Accession number :
39315853
Full Text :
https://doi.org/10.1096/fj.202401200R