Back to Search Start Over

Dual-energy Computed Tomography (DECT) predicts the efficacy of contrast medium extravasation and secondary cerebral hemorrhage after stent thrombectomy in acute ischemic cerebral infarction.

Authors :
Qiu T
Feng H
Shi Q
Fu S
Deng X
Chen M
Li H
Zhang Z
Xu X
Xiao H
Wang Z
Yu X
Tang J
Dai X
Source :
Biotechnology & genetic engineering reviews [Biotechnol Genet Eng Rev] 2024 Apr; Vol. 40 (1), pp. 202-216. Date of Electronic Publication: 2023 Mar 09.
Publication Year :
2024

Abstract

To prospective research the efficacy of dual-energy computed tomography (DECT) in predicting contrast medium extravasation and secondary cerebral hemorrhage after stent thrombectomy in acute ischemic cerebral infarction. Ninety-two patients with acute ischemic stroke who underwent intra-arterial thrombolysis in our hospital from December 2019 to January 2022 have opted as the study subjects. DECT was performed immediately after stent thrombectomy. Images were generated through the image workstation and routine diagnosis was performed 24 hours after the operation. To analyze the diagnostic value of To analyze the diagnostic value of DECT, and to explore the diagnostic status of lesions with hemorrhagic transformation or increased hemorrhage and their correlation with iodine concentration. (1) 68 situations were confirmed, 56 positive and 12 negative with detection rates of 10.71% for hemorrhage, 75.00% for contrast agent extravasation, and 14.29% for extravasation combined with hemorrhage; (2) DECT diagnosed 8 cases of postoperative bleeding and 44 cases of extravasation of contrast media and 4 cases of extravasation of contrast media with hemorrhage ; The accuracy of DECT in diagnosing postoperative hemorrhage was 96.43%. The accuracy of diagnosis of extravasation was 96.43%. (3) The mean iodine concentration of lesions with increased hemorrhage or hemorrhagic transformation was higher compared to those without; (4) There was a correlation between hemorrhagic transformation or increased hemorrhage and iodine concentration. Dual-energy CT (DECT) can accurately distinguish the extravasation of contrast agent and secondary cerebral hemorrhage, and can predict the increased bleeding and bleeding transformation, with good diagnostic value and good predictive efficacy.

Details

Language :
English
ISSN :
2046-5556
Volume :
40
Issue :
1
Database :
MEDLINE
Journal :
Biotechnology & genetic engineering reviews
Publication Type :
Academic Journal
Accession number :
39312182
Full Text :
https://doi.org/10.1080/02648725.2023.2183311