Standardized Temporary Atrial Epicardial Wire Locations Lead to Enhanced Atrial Signal Identification.
- Source :
-
Journal of intensive care medicine [J Intensive Care Med] 2024 Sep 19, pp. 8850666241279229. Date of Electronic Publication: 2024 Sep 19. - Publication Year :
- 2024
- Publisher :
- Ahead of Print
-
Abstract
- Background: Arrhythmias, common after pediatric cardiac surgery, are associated with increased morbidity and mortality. Atrial epicardial wires (AEW) improve diagnostic accuracy but have variable pacing and sensing properties based on their location. Even so, there are no longitudinal prospective pediatric studies examining ideal placement of AEW. Methods: This multicenter study compared atrial amplitudes, pacing sensitivities and thresholds via AEW placed at Bachmann's Bundle (BB) and the interatrial groove near the right pulmonary veins (IGRPV) versus the surgeons' standard locations. An AtriAmp system was used to obtain an atrial ECG to calculate atrial and ventricular amplitude from atrial electrograms on the bedside monitor. Sensitivities and thresholds via a temporary pacemaker were documented. ANOVA tests with repeated measures and post-hoc pairwise comparisons were performed to compare variables within the first 24-h postoperative hours. Mixed effects linear regression models were employed to examine daily trends. Results: In the first 24-h following cardiac surgery, AEW at BB and IGRPV showed significantly larger atrial amplitudes than the surgeons' standard locations. In addition, there was a negative trend in atrial ECG amplitude in all AEW from postoperative days 0 to 1; however, subsequent days showed a positive mean change in atrial amplitude with largest increase seen at BB. Atrial sensing as measured by the temporary pacemaker had statistically greater atrial signal amplitude from the BB-IGRPV set in both polarities (ie, with the BB as the - or + electrode pair) as compared to the surgeons' standard locations. No difference in atrial thresholds (mA) were noted in the immediate postoperative period or over time, with a relatively low atrial threshold at all sites. Conclusion: Standardization of AEW at Bachmann's Bundle can yield largest atrial amplitudes by atrial ECG and highest atrial sensing parameters without compromising atrial thresholds.<br />Competing Interests: Declaration of Conflicting InterestsThe authors declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.
Details
- Language :
- English
- ISSN :
- 1525-1489
- Database :
- MEDLINE
- Journal :
- Journal of intensive care medicine
- Publication Type :
- Academic Journal
- Accession number :
- 39295470
- Full Text :
- https://doi.org/10.1177/08850666241279229