Eco-friendly second derivative synchronous fluorescence spectroscopic method for simultaneous determination of rosuvastatin and ezetimibe in pharmaceutical capsules.
- Source :
-
Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy [Spectrochim Acta A Mol Biomol Spectrosc] 2025 Jan 15; Vol. 325, pp. 125123. Date of Electronic Publication: 2024 Sep 10. - Publication Year :
- 2025
-
Abstract
- The fixed dose combination of Rosuvastatin and ezetimibe has recently received approval from the FDA for the treatment of elevated levels of low-density lipoprotein cholesterol in adults. Herein, an eco-friendly and highly sensitive spectrofluorimetric method was developed and validated for simultaneous determination of rosuvastatin and ezetimibe in commercial capsules. The developed method involved synchronous fluorescence spectroscopy combined with second derivative spectroscopy to resolve the overlapping fluorescence spectra of rosuvastatin and ezetimibe. The studied drugs were measured in synchronous mode at Δλ of 40 and their recorded synchronous fluorescence spectra were derivatized into second-order spectra, enabling the selective quantification of rosuvastatin and ezetimibe at 370 nm and 312 nm, respectively. Optimization studies regarding to the influence of buffer pH, incorporation of surfactant, choice of diluting solvent, and synchronous Δλ were carried out. The method was validated using the validation characteristics listed in ICH Q2(R1). The calibration curves displayed satisfactory linear relationships across the calibration range of 0.1-2 µg/mL for rosuvastatin and 0.05-3 µg/mL for ezetimibe. The methodology demonstrated robustness to minor modifications in the procedural parameters and selectivity in quantifying the studied drugs in synthetic mixed solutions and commercial capsules without interference. Furthermore, the level of environmental friendliness and sustainability of the suggested spectrofluorimetric approach was assessed in relation to two previously documented methodologies utilizing the AGREE metric. The findings indicated that the suggested method demonstrated a notably superior level of sustainability in comparison to the documented methods.<br />Competing Interests: Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.<br /> (Copyright © 2024 Elsevier B.V. All rights reserved.)
- Subjects :
- Reproducibility of Results
Hydrogen-Ion Concentration
Limit of Detection
Solvents chemistry
Green Chemistry Technology methods
Anticholesteremic Agents analysis
Anticholesteremic Agents chemistry
Rosuvastatin Calcium analysis
Ezetimibe analysis
Ezetimibe chemistry
Spectrometry, Fluorescence methods
Capsules
Subjects
Details
- Language :
- English
- ISSN :
- 1873-3557
- Volume :
- 325
- Database :
- MEDLINE
- Journal :
- Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy
- Publication Type :
- Academic Journal
- Accession number :
- 39288605
- Full Text :
- https://doi.org/10.1016/j.saa.2024.125123