Back to Search Start Over

Fe 3 O 4 @gC 3 N 4 @Thiamine: a novel heterogeneous catalyst for the synthesis of heterocyclic compounds and microextraction of tebuconazole in food samples.

Authors :
Peiman S
Maleki B
Ghani M
Source :
Scientific reports [Sci Rep] 2024 Sep 14; Vol. 14 (1), pp. 21488. Date of Electronic Publication: 2024 Sep 14.
Publication Year :
2024

Abstract

Graphite carbon nitride (g-C <subscript>3</subscript> N <subscript>4</subscript> ) is a two-dimensional nano-sheet with electronic properties, which shows unique characteristics with high chemical and thermal stability in its structure. The functionalization of these compounds through covalent bonding is an important step towards significantly improving their properties and capabilities. To achieve this goal, a novel strategy for the covalent functionalization of Fe <subscript>3</subscript> O <subscript>4</subscript> @g-C <subscript>3</subscript> N <subscript>4</subscript> with thiamine hydrochloride (vitamin B1) via cyanuric chloride (TCT), which is a divalent covalent linker, was presented. The efficiency of Fe <subscript>3</subscript> O <subscript>4</subscript> @gC <subscript>3</subscript> N <subscript>4</subscript> @Thiamine as a heterogeneous organic catalyst in the synthesis of spirooxindole-pyran derivatives and 2-amino-4H-pyran under solvent-free conditions was evaluated and the yields of high-purity products were presented. In addition, easy recycling and reuse for seven consecutive cycles without significant reduction in catalytic activity are other features of this catalyst. Moreover, the performance of the prepared sorbent in the microextraction technique (herein, magnetic solid phase extraction) was studied. The tebuconazole was selected as the target analyte. The target analyte was extracted and determined by HPLC-UV. Under the optimum condition, the linear range of the method (LDR) was estimated in the range of 0.2-100 μg L <superscript>-1</superscript> (the coefficient of determination of 0.9962 for tebuconazole). The detection limit (LOD) of the method for tebuconazole was calculated to be 0.05 µg L <superscript>-1</superscript> . The limit of quantification (LOQ) of the method was also estimated to be 0.16 µg L <superscript>-1</superscript> . In order to check the precision of the proposed method, the intra-day and inter-day relative standard deviations (RSD%) were calculated, which were in the range of 1.5- 2.8%. The method was used for the successful extraction and determination of tebuconazole in tomato, cucumber, and carrot samples.<br /> (© 2024. The Author(s).)

Details

Language :
English
ISSN :
2045-2322
Volume :
14
Issue :
1
Database :
MEDLINE
Journal :
Scientific reports
Publication Type :
Academic Journal
Accession number :
39277597
Full Text :
https://doi.org/10.1038/s41598-024-72212-6