Back to Search Start Over

Error Analysis and Optimization of Structural Parameters of Spatial Coordinate Testing System Based on Position-Sensitive Detector.

Authors :
Lu H
Chu W
Zhang B
Zhao D
Source :
Sensors (Basel, Switzerland) [Sensors (Basel)] 2024 Sep 04; Vol. 24 (17). Date of Electronic Publication: 2024 Sep 04.
Publication Year :
2024

Abstract

For the research on real-time accurate testing technology for the explosion point spatial coordinate of munitions, its currently commonly used methods such as acoustic-electric detection or high-speed imaging are limited by the field conditions, response rate, cost, and other factors. In this paper, a method of spatial coordinate testing for the explosion point based on a 2D PSD (position-sensitive detector) intersection is proposed, which has the advantages of a faster response, better real-time performance, and a lower cost. Firstly, a mathematical model of the spatial coordinate testing system was constructed, and an error propagation model for structural parameters was developed. The influence of the position of the optical axes' intersection as well as the azimuth angle and pitch angle on the test accuracy of the system was simulated and analyzed, thus obtaining the distribution and variation trend of the overall error propagation coefficient of the system. Finally, experiments were designed to obtain the test error of the system for validation. The results show that the system test accuracy is high when the azimuth angle is 20°-50°, the overall error propagation coefficient does not exceed 48.80, and the average test error is 56.17 mm. When the pitch angle is -2.5°-2.5°, the system has a higher test accuracy, with the overall error propagation coefficient not exceeding 44.82, and the average test error is 41.87 mm. The test accuracy of the system is higher when the position of the optical axes' intersection is chosen to make sure that explosion points fall in the region of the negative half-axis of the Zw-axis of the world coordinate system, with an overall error propagation coefficient of less than 44.78 and an average test error of 73.38 mm. It is shown that a reasonable selection of system structure parameters can significantly improve the system test accuracy and optimize the system deployment mode under the long-distance field conditions so as to improve the deployment efficiency.

Details

Language :
English
ISSN :
1424-8220
Volume :
24
Issue :
17
Database :
MEDLINE
Journal :
Sensors (Basel, Switzerland)
Publication Type :
Academic Journal
Accession number :
39275651
Full Text :
https://doi.org/10.3390/s24175740